[Symptom]
Press start then maintenance lamp will light “RED”, when the “ERROR Log-
ERROR 3 or 6” will show the 01.
[Cause]
1. The 8-pin console cable is damaged.
2. Incline motor is damaged.
3. TV is damaged.
4. MCB is damaged.
5. The incline setting is not correct.
[Solution]
1. Please check the incline motor cable whether to inset MCB.
2. Check the console signal whether transmission to MCB, you can refer to MCB
LED UP and DOWN. If LED not light please check the console cable and
console. If LED have light please replace the incline motor
3. If “ERROR Log- ERROR 3 or 6” still show the 01, please replace the incline
motor.
4. If “ERROR Log- ERROR 3 or 6” still show the 01, please replace the TV.
5. If “ERROR Log- ERROR 3 or 6” still show the 01 , please replace the MCB.
6. Enter Engineering Mode to renew the
Auto-calibration( Engineer mode P15)
.
Error message 3,6 troubleshooting
MCB LED UP and DOWN LED
whether have light.
Содержание T8000E
Страница 1: ...1 2006 Johnson T8000E TM97 SERVICE MANUAL ...
Страница 3: ...3 SECTION 1 MAINTENANCE PROCEDURE ...
Страница 12: ...12 SECTION 2 WIRING DIAGRAM INSTRUCTION ...
Страница 13: ...13 T8000E TM97 MCB WIRING 220V J1 P2 P3 J2 MTR2 L2 L1 MTR1 P4 P1 ...
Страница 16: ...16 T8000E TM97 Electrical block diagram for 220V Lout L Return R Return Rout GND ...
Страница 17: ...17 SECTION 3 CONSOLE ENGINEER MODE ...
Страница 19: ...19 The list manager s custom setting ...
Страница 20: ...20 ...
Страница 21: ...21 ...
Страница 22: ...22 SECTION 4 MCB LED INSTRUCTIONS ...
Страница 24: ...24 SECTION 5 TROUBLESHOOTINGS ...
Страница 33: ...33 SECTION 6 What is the difference between 2006 T8000 TM95 2006 T8000E TM97 ...
Страница 34: ...34 T8000E TM97 Console is 15 TFT TV T8000 TM95 Console is 7 LCD ...