Section 4: Programming Options
can still be done if this option is programmed with a valid
public APN.
Default:
Blank
Valid range:
32 characters ASCII
CMS Cellular 2 Domain Name
This information is provided by the central monitoring station
system administrator.
Default:
Blank
Valid range:
32 characters ASCII
4.3.1 Other Communicator Related
Options
Alternate Test Transmission
When this option is enabled, the test transmission alternates
between primary and secondary receivers with each test
transmission interval.
When disabled, the test transmission is sent to the pro-
grammed receivers, based on the settings of the periodic
test transmission reporting codes.
Default:
Enabled
Valid range:
Enabled/Disabled
Ethernet Test Transmission Time
Enter a 4-digit number (0000-2359) using the 24-hour clock
format (HHMM) to set the time of day an Ethernet test trans-
mission is sent. Programming a value of 9999 disables the
test transmission time.
Note:
The internal date and time is automatically pro-
grammed when the unit communicates with the primary
receiver.
Default:
9999
Valid range:
0000 to 2359, 9999 to disable
Ethernet Test Transmission Cycle
This option is used to program how often, in minutes, Eth-
ernet test transmissions are sent. Once the initial test trans-
mission is sent, all future test transmissions are offset by the
programmed number of days.
Default:
0 minutes. (Note: Test transmission shall be 24 hours for ULC and 7
days for UL)
Valid
range:
000000 (disabled) to 999999 minutes.
Note:
Programming an interval of less than 5 minutes or a
value greater than 999999 disables the test transmission.
Cellular Test Transmission Time
Enter a 4-digit number (0000-2359) using the 24-hour clock
format (HHMM) to set the time of day a cellular test trans-
mission is sent. Programming a value of 9999 disables the
test transmission time.
Note:
The internal date and time will automatically be pro-
grammed when the unit communicates with the primary
receiver.
Default:
9999
Valid range:
0000 to 2359, 9999 to disable
Cellular Test Transmission Cycle
This option is used to program how often, in minutes, cel-
lular test transmissions are sent. Once the initial test trans-
mission is sent, all future test transmissions are offset by the
programmed number of minutes.
Default: 0 minutes. (Note: When only cellular is used, test transmission shall be
24 hours for ULC and 7 days for UL.)
Valid
range:
000000 to 999999 minutes
Note:
Programming an interval of less than 5 minutes or a
value greater than 999999 disables the test transmission.
Commercial Supervision
When this option is enabled, swap detection is provided on
the supervisory packet. When disabled, only supervision of
the communicator path to the receiver is provided.
Default:
Enabled
Valid range:
Enabled/Disabled
Ethernet Supervision Interval (Heartbeat)
This option is used to set the frequency (in seconds) when
supervisory heartbeats are sent to the Ethernet receiver. If
the programmed value is 000 seconds, supervision is dis-
abled.
Note:
Commercial Supervision must be enabled in order to
test the communications path.
Default:
000
Valid range:
001 to 255 Seconds, 000 to Disable
Cellular Supervision Interval ( Heartbeat)
This option is used to set the frequency (in seconds) when
supervisory heartbeats are sent to the cellular receiver. If the
programmed value is 000 seconds, supervision is disabled.
Note:
Commercial Supervision must be enabled in order to
test the communications path.
Default:
000
Valid range:
001 to 255 Seconds, 000 to Disable
CMS Event Heartbeat Interval
This option is used to program the periodic heartbeat inter-
val between the alarm panel and the cellular communicator.
The heartbeat is used to monitor for image/audio file
requests.
Default:
15 Seconds, 0 to disable
Valid range:
000 to 255 Seconds
- 24 -