Ordering 

Procedure

Contact your local distributor for avail-

ability. When placing an order, indicate 

the full product name and Part Number 

(P/N).

Sprinkler Assemblies with NPT 

Thread Connections

Specify: Series TY-L (specify SIN), 

(specify K-factor), (specify Upright, 

Pendent, or Recessed Pendent) Sprin-

kler, Standard Response, Standard 

Coverage, (specify) temperature rating, 

(specify) finish or coating, P/N (specify 

from Table C)

Recessed Escutcheon

Specify: Style (specify) Recessed 

Escutcheon, (specify material) with 

(specify*) finish, P/N (specify*)

*Refer to Technical Data Sheet TFP770

Sprinkler Wrench

Specify: W-Type 9 Sprinkler Wrench, 

P/N 56-000-1-849
Specify: W-Type 10 Sprinkler Wrench, 

P/N 56-000-1-948

Wax Sticks (for retouching wrench-

damaged wax coating)

Specify: Series TY-L Sprinklers, 

(specify color), color coded Wax Stick 

for retouching, (specify) temperature 

rated, P/N (specify):

Red for 165°F (74°C)  . . . . . . .  P/N 56-065-1-155

Blue for 212°F (100°C)
and 280

°

F (138

°

C)  . . . . . . . . . P/N 56-065-1-286

Note:

 Each wax stick is suitable for 

retouching up to twenty-five sprinklers. 

The wax used for 280°F (138°C) sprinklers 

is the same as for 212°F (100°C)sprinklers. 

Therefore, the 280°F (138°C) sprinkler 

is limited to the same maximum ceiling 

temperature as the 212°F (100°C) sprinkler, 

which is 150°F (65°C).

completed, to verify the integrity of the 

corrosion-resistant coating. Thereafter, 

annual inspections per NFPA 25 should 

suffice; however, instead of inspecting 

from the floor level, a random sampling 

of close-up visual inspections should 

be made so as to better determine the 

exact sprinkler condition and the long-

term integrity of the corrosion resistant 

coating, as it may be affected by the 

corrosive conditions present.
The owner is responsible for the 

inspection, testing, and maintenance of 

their fire protection system and devices 

in compliance with this document, as 

well as with the applicable standards 

of the NATIONAL FIRE PROTECTION 

ASSOCIATION, such as, NFPA 25, in 

addition to the standards of any other 

authorities having jurisdiction. Contact 

the installing contractor or product 

manufacturer with any questions.
It is recommended that automatic 

sprinkler systems be inspected, tested, 

and maintained by a qualified Inspec-

tion Service in accordance with local 

requirements and/or national codes.

SIN

111 5.6K UPRIGHT (1/2 in. NPT) TY3111

112 5.6K PENDENT (1/2 in. NPT) TY3211

101 8.0K UPRIGHT (3/4 in. NPT) TY4111

102 8.0K PENDENT (3/4 in. NPT) TY4211

106 8.0K UPRIGHT (1/2 in. NPT) TY4811

107 8.0K PENDENT (1/2 in. NPT) TY4911

SPRINKLER 

FINISH

1

NATURAL BRASS

6

WAX COATED 

165°F TO 280°F ONLY

7

LEAD COATED

8

WAX OVER LEAD 

165°F TO 212°F ONLY

9

CHROME PLATED

TEMPERATURE 

RATING

165

165°F (74°C)

212

212°F (100°C)

280

280°F (138°C)

P/N 53 - XXX - X - XXX

TABLE C 

SERIES TY-L PENDENT AND UPRIGHT SPRINKLERS 

PART NUMBER SELECTION

Содержание tyco TY-L Series

Страница 1: ...ve passed the standard corrosion tests of the applicable approval agen cies the testing is not representative of all possible corrosive atmospheres Consequently it is recommended that the end user be consulted about the suitability of these coatings for any given corrosive environment The effects of ambient temperature con centration of chemicals and gas chemical velocity should be consid ered as ...

Страница 2: ...on Deflector 3 7 6 5 4 2 1 5 Strut Ejection 3 Frame 1 Element Fusible Sealing Button 2 Spring 4 Deflector 7 6 Hook 3 4 NPT 2 7 8 73 0 mm DIA 2 11 16 68 3 mm 2 11 16 68 3 mm 1 2 12 7 mm NOMINAL MAKE IN UPRIGHT PENDENT CROSS SECTION RECESSED PENDENT 2 5 8 66 7 mm 7 16 11 1 mm NOMINAL MAKE IN 2 5 8 66 7 mm 2 50 8 mm WRENCH FLANGES ESCUTCHEON PLATE SEATING SURFACE 2 7 8 73 0 mm DIA WRENCH AREA 3 STYLE...

Страница 3: ...nted 1 2 3 N A6 212 F 100 C White 1 2 3 NOTES 1 UL Listed 2 C UL Listed 3 FM Approved 4 FM Approved for maximum 150 F 68 C ambient temperatures 5 LPCB Approved LPCB Ref No 094a 03 6 Not Available N A K Factor Type Temperature Rating Frame Color Code Sprinkler Finish Natural Brass Chrome Plated Lead Coated Wax Coated Wax Over Lead Coated 8 0 3 4 in NPT Upright TY4111 165 F 74 C Unpainted 1 2 3 5 1 ...

Страница 4: ... 8 3 2 mm 2 7 8 DIA 73 0 mm 1 2 12 7 mm MOUNTING SURFACE FACE OF SPRINKLER FITTING 7 16 1 8 11 1 3 2 mm 2 1 4 DIA 57 2 mm MOUNTING PLATE 1 8 3 2 mm 2 7 8 DIA 73 0 mm CLOSURE TY L 1 1 2 38 1 mm 1 3 4 44 5 mm 1 4 6 4 mm 1 2 12 7 mm MOUNTING SURFACE FACE OF SPRINKLER FITTING 7 16 1 8 11 1 3 2 mm 2 1 4 DIA 57 2 mm MOUNTING PLATE 1 8 3 2 mm 2 7 8 DIA 73 0 mm CLOSURE 1 4 6 4 mm TY L 1 1 2 38 1 mm 1 3 4 ...

Страница 5: ...rdance with this section Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified Absence of an escutcheon which is used to cover a clearance hole may dela...

Страница 6: ...ching up to twenty five sprinklers The wax used for 280 F 138 C sprinklers isthesameasfor212 F 100 C sprinklers Therefore the 280 F 138 C sprinkler is limited to the same maximum ceiling temperatureasthe212 F 100 C sprinkler which is 150 F 65 C completed to verify the integrity of the corrosion resistant coating Thereafter annual inspections per NFPA 25 should suffice however instead of inspecting...

Отзывы: