background image

TFP296

Page 7 of 8

3/4" (19,1 mm)

1-1/4" (31,8 mm)

CLOSURE

1/4" (6,4 mm)

3/4" (19,1 mm)

5/8±1/4"

(15,9±6,4 mm)

MOUNTING

PLATE

MOUNTING

SURFACE

FACE OF

SPRINKLER

FITTING

2-1/4" DIA.

(57,2 mm)

2-7/8" DIA.

(73,0 mm)

SERIES

TY-FRB EC

1/8"

(3,2 mm)

MOUNTING

PLATE

MOUNTING

SURFACE

FACE OF

SPRINKLER

FITTING

CLOSURE

2-1/4" DIA.

(57,2 mm)

2-7/8" DIA.

(73,0 mm)

SERIES

TY-FRB EC

1" (25,4 mm)

1-1/4" (31,8 mm)

1/4" (6,4 mm)

1/2" (12,7 mm)

1/8"

(3,2 mm)

1/2±1/8"

(12,7±3,2 mm)

3/4" (19,1 mm)

1-1/4" (31,8 mm)

CLOSURE

1/4" (6,4 mm)

3/4" (19,1 mm)

5/8±1/4"

(15,9±6,4 mm)

MOUNTING

PLATE

MOUNTING

SURFACE

FACE OF

SPRINKLER

FITTING

2-1/4" DIA.

(57,2 mm)

2-7/8" DIA.

(73,0 mm)

SERIES

TY-FRB EC

1/8"

(3,2 mm)

1" (25,4 mm)

1-1/4" (31,8 mm)

CLOSURE

1/4" (6,4 mm)

1/2" (12,7 mm)

MOUNTING

PLATE

MOUNTING

SURFACE

FACE OF

SPRINKLER

FITTING

2-1/4" DIA.

(57,2 mm)

2-7/8" DIA.

(73,0 mm)

SERIES

TY-FRB EC

1/8"

(3,2 mm)

1/2±1/8"

(12,7±3,2 mm)

FIGURE 5 

SERIES TY-FRB RECESSED EC SIDEWALL 

SPRINKLER ASSEMBLY WITH TWO-PIECE 

3/4 INCH TOTAL ADJUSTMENT 

STYLE 10 RECESSED ESCUTCHEON 

5.6 K-FACOTR, 1/2 INCH NPT

FIGURE 6 

SERIES TY-FRB RECESSED EC SIDEWALL 

SPRINKLER ASSEMBLY WITH TWO-PIECE 

1/2 INCH TOTAL ADJUSTMENT 

STYLE 20 RECESSED ESCUTCHEON 

5.6 K-FACTOR, 1/2 INCH NPT

FIGURE 7 

SERIES TY-FRB RECESSED EC SIDEWALL 

SPRINKLER ASSEMBLY WITH TWO-PIECE 

3/4 INCH TOTAL ADJUSTMENT 

STYLE 40 RECESSED ESCUTCHEON 

8.0 K-FACTOR, 3/4 INCH NPT

FIGURE 8 

SERIES TY-FRB RECESSED EC SIDEWALL 

SPRINKLER ASSEMBLY WITH TWO-PIECE 

1/2 INCH TOTAL ADJUSTMENT 

STYLE 30 RECESSED ESCUTCHEON 

8.0 K-FACTOR, 3/4 INCH NPT

Содержание tyco TY-FRB Series

Страница 1: ...r utilizes either a two piece Style 10 1 2 in NPT or Style 40 3 4 in NPT Recessed Escutch eon with 1 2 in 12 7 mm of recessed adjustment or up to 3 4 in 19 1 mm of total adjustment from the flush side wall position or a two piece Style 20 1 2 in NPT or Style 30 3 4 in NPT Recessed Escutcheon with 1 4 in 6 4 mm of recessed adjustment or up to 1 2 in 12 7 mm of total adjustment from the flush sidewa...

Страница 2: ...s as outlined in the appliable installation standard recognized by the Approval Agency e g UL recognizes NFPA 13 and FM recognize the FM Loss Preven tion Data Sheets Only the Style 10 20 30 or 40 Recessed Escutcheon as applicable is to be used for recessed installations 2 5 4 6 1 3 WRENCH FLATS 1 1 2 38 1 mm 2 3 16 55 6 mm 7 16 11 1 mm NOMINAL MAKE IN 1 9 16 39 7 mm DEFLECTOR HAT 1 2 NPT 7 7 16 11...

Страница 3: ...tual Research Corporation FM per Table D 4 Approved by the City of New York under MEA 354 01 E 5 Where Polyester Coated Sprinklers are noted to be UL and C UL Listed the sprinklers are UL and C UL Listed corrosion resistant sprinklers a Installed with Style 10 1 2 in NPT or Style 40 3 4 in NPT 3 4 in Total Adjustment Recessed Escutcheon as applicable b Installed with Style 20 1 2 in NPT or Style 3...

Страница 4: ...4 0 5 Quick 16 x 22 4 9 x 6 7 36 136 20 3 1 59 4 to 12 100 to 300 135 10 3 1 13 4 0 5 Quick 16 x 24 4 9 x 7 3 39 148 23 8 1 64 4 to 6 100 to 150 135 10 3 1 13 4 0 5 Quick 16 x 24 4 9 x 7 3 40 151 25 0 1 72 4 to 12 100 to 300 135 10 3 1 13 4 0 5 Standard 16 x 20 4 9 x 6 1 32 121 16 0 1 10 4 to 6 100 to 150 155 10 3 1 13 4 0 5 Standard 16 x 20 4 9 x 6 1 33 125 17 0 1 17 4 to 12 100 to 300 155 10 3 1...

Страница 5: ...6 20 1 38 4 to 12 100 to 300 135 155 10 3 1 Quick 16 x 20 4 9 x 6 1 40 151 25 1 72 4 to 12 100 to 300 135 155 10 3 1 Quick 16 x 22 4 9 x 6 7 44 167 30 2 06 4 to 12 100 to 300 135 155 10 3 1 Quick 16 x 24 4 9 x 6 7 48 182 36 2 48 4 to 12 100 to 300 135 155 10 3 1 Standard 16 x 16 4 9 x 4 9 32 121 16 1 10 4 to 12 100 to 300 175 10 3 1 Standard 16 x 18 4 9 x 5 5 36 136 20 1 38 4 to 12 100 to 300 175 ...

Страница 6: ...6 and 8 0 K factor Extended Coverage Horizon tal Sidewall Sprinklers Quick and Stan dard Response Light Hazard must be maintained and serviced in accordance with this section Before closing a fire protection system main control valve for maintenance work on the fire pro tection system that it controls per mission to shut down the affected fire protection system must be obtained from the proper aut...

Страница 7: ...m 1 1 4 31 8 mm CLOSURE 1 4 6 4 mm 1 2 12 7 mm MOUNTING PLATE MOUNTING SURFACE FACE OF SPRINKLER FITTING 2 1 4 DIA 57 2 mm 2 7 8 DIA 73 0 mm SERIES TY FRB EC 1 8 3 2 mm 1 2 1 8 12 7 3 2 mm FIGURE 5 SERIES TY FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO PIECE 3 4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5 6 K FACOTR 1 2 INCH NPT FIGURE 6 SERIES TY FRB RECESSED EC SIDEWALL SPRINKLE...

Страница 8: ...rt Number P N Sprinkler Assembly with NPT Thread Connections Specify Series TY FRB specify SIN Extended Coverage Horizontal Side wall Sprinkler K specify specify temperature rating specify finish P N specify from Table E Recessed Escutcheon Specify Style 10 20 30 or 40 Recessed Escutcheon with specify finish P N specify Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify W Type 6 Sprinkl...

Отзывы: