Enrolling the module
Before you enroll the module, ensure that all hardwired zones, PGM, AUX, and BELL are wired to the
module.
To enroll the module, complete the following steps:
1. Enable enrollment through panel programming. For more information, refer to the
Qolsys
IQPanel2 or Qolsys IQPanel4 Installation Manual.
2. Press the
Enroll
button on the PCB and release when the LED lights solid orange.
3. Confirm the correct module ID in panel programming.
Note:
The module ID is on the module label. It is a seven digit number that identifies the
device being enrolled. It has the format 460-XXXX.
Testing the module placement
To test the signal strength between the module and the alarm panel, complete the following steps:
•
Press the
Enroll
button on the module.
After the placement test is complete, the color of the LED indicates the signal strength. For more
Table 11: Device signal strength
LED color
Signal strength
Three red flashes
Poor
Three orange flashes
Medium
Three green flashes
Strong
Note:
For UL and ULC installations, only a strong signal strength is acceptable.
25