User Manual: NEO System
42
Rev.0.3
configuration of FlexNet and of interconnected elements through this system, it is necessary to
use the configuration software.
To make a FlexNet connection between compatible devices, connect the ports as shown in
Picture. Make sure all devices are part of the same network (see section 3.5.3).
Figure 44 - FlexNet
The bandwidth that Flexnet occupies in the standard Ethernet network is of 25Mb/s. On
Ethernet networks of 100Mb/s, it works at network layer 2 for audio and layer 3 for
communications.
Operation of the connection between NEO devices:
The return connection to port B will be generally on standby. It will activate automatically if a
loss of connection between devices is detected. If connection cannot be recovered, it will turn
on standby and a 'LINK' failure will be shown until a manual reboot. If the system works
correctly using the redundant link, the system will show the following failure: 'Network backup
link active'.