Product Code

M9320-HGA-4

M9320-AUA-4

Control Type

On/Off Floating 

Proportional

On/Off Floating

Power Requirements

24 VAC ± 20%, 5.7 VA running 
24 VDC ± 10%, 2.1 W running

Norminal AC 230 V at 50Hz: 0.04

Transformer Sizing Requirements 

≥ 7 VA

Input Signal/Adjustments

24 VAC ±20%,

24 VDC ± 10%

DC 0 (2) to 10 V or 0 

(4) to 20 mA with field 

furnished 500 ohm 1/4 W 

resistor

Offset: DC 0 to 10 V

Span: DC 2 to 10 V

AC 100 to 240V (AC 85 to 265 V) at 

50/60 Hz

Control Impedance

4.7k ohm 

100k ohm

Feedback Signal

DC 0 (2) to 10 V

Running Torque

20 Nm (180 lb

in)

Rotation Time

90 s

Rotation Time Autocalibration

35 s

Product Code

M9335-HGA-4

M9335-AUA-4

Control Type

On/Off Floating 

Proportional

On/Off Floating

Power Requirements

24 VAC ± 20%, 6.1 VA running 
24 VDC ± 10%, 2.1 W running

Norminal AC 230 V at 50Hz: 0.04

Transformer Sizing Requirements 

≥ 7 VA

Input Signal/Adjustments

24 VAC ±20%,

24 VDC ± 10%

DC 0 (2) to 10 V or 0 

(4) to 20 mA with field 

furnished 500 ohm 1/4 W 

resistor

Offset: DC 0 TO 10 V

Span: DC 2 to 10 V

AC 100 to 240 V (AC 85 to 265 V) at 

50/60 Hz

Control Impedance

4.7k ohm 

100k ohm

Feedback Signal

DC 0 (2) to 10 V

Running Torque

35 Nm (310 lb

in)

Rotation Time

150 s

Rotation Time Autocalibration

75 s

Technical Specifications

This product is covered by a limited warranty, details of which can be found at 

www.johnsoncontrols.com/buildingswarranty

.

Patents: 

http://jcipat.com

Product warranty

Patents

Содержание M9320-AUA-4

Страница 1: ...uator for dampers 14 01480 00014 Rev A November 2019 Installation Guide 140148000014Rev A Figure 1 M9335 HGA Actuator Parts Included Warnings IP54 LISTED 654U TEMP REG EQUIP CLASS 2 MAX 60 C 140 F MIN 30 C 22 F MAX 95 RH M93xx xGx xx M93xx xUx xx LISTED 654U TEMP REG EQUIP ...

Страница 2: ... M9335 HGA 4 M9335 AUA 4 14 01480 00014 Rev A 2 Dimensions mm 201 192 163 9 2 103 66 63 60 30 30 5 39 Figure 2 The diagrams below illustrate the model dimensions of the M9300 Actuator Adjusting the angular rotation A C B D E ...

Страница 3: ...Управление COM 2 3 1 4 RED GRY BLK ORN 0 to 10 VDC 0 2 to 10 VDC 24 V AC DC 2 3 1 4 RED GRY BLK ORN COM 500 Ω 1 4 W 0 4 to 20 mA 0 to 10 VDC 24 V AC DC Floating Control Commande flottante 3 Punkt Regelung Controllo flottante Control flotante Variabele regeling Flytande styrenhet Integrační regulace Sterowanie astatyczne Трехпозиционное регулирование External resistor Résistance externe Externen Wi...

Страница 4: ...4 VAC 85 264 VAC ORN 2 3 1 Floating Control COM On Off Control Commande marche arrêt Auf Zu Regelung Controllo On Off Control de encendido apagado Aan uit regeling PÅ AV styrenhet Regulace vypnutím zapnutím Sterowanie ON OFF Двухпозиционное регулирование ВКЛ ВЫКЛ Floating Control Commande flottante 3 Punkt Regelung Controllo flottante Control flotante Variabele regeling Flytande styrenhet Integrač...

Страница 5: ...10 0 10 Span Adj Offset Adj Enter Autocal M9320 HGA 4 M9335 HGA 4 Example Command Signal Feedback Signal Setting User Interface 1 0 to 10 VDC Direct 0 to 10 VDC DA RA 2 10 0 10 2 0 to 10 VDC Reverse 0 to 10 VDC DA RA 2 10 0 10 3 2 to 10 VDC Direct 2 to 10 VDC DA RA 2 10 0 10 24 VAC 4 Offset 5 Active 2 to 10 VDC DA RA 2 10 0 10 Span 7 Refer to Setting the SPAN and OFFSET Proportional command signal...

Страница 6: ... AC DC value OFFSET value INC LED LED LED If desired value is reached 10s LED LED LED Span Adj Offset Adj ENTER AUTOCAL LED LED LED 3s OK value INC LED LED LED 1x Span value 0 5 VDC 2x Span value 1 0 VDC 3x Span value 1 5 VDC If desired value is reached 10s LED LED Span Adj Offset Adj ENTER AUTOCAL LED LED 3s LED OK SPAN value 1 2 3 4 5 6 7 8 9 10 11 12 13 14 LED Span Adj Offset Adj ENTER AUTOCAL ...

Страница 7: ...i impiego di conduttori flessibili usare degli ancoraggi per cavi Assicurarsi che il valore della tensione di alimentazione corrisponda a quello prestabilito dell attuatore Prima di inserire l azionamento controlare tutti gli allacciamenti dei cavi Il contatto con componenti sottoposti a tensioni pericolose può causare scosse elettriche con conseguenti lesioni gravi o morte I cavi in corto circuit...

Страница 8: ...и правилам и должны выполняться только уполномоченным персоналом Прокладывайте цепи высокого и низкого напряжения отдельно В случае применения много жильного провода заключите конец провода в наконечник Удостоверьтесь в том что напряжение питающей сети соответствует напряжению питания которое указано на корпусе устройства Проверьте все проводные соединения прежде чем подавать питание на систему Пр...

Страница 9: ... s Rotation Time Autocalibration 35 s Product Code M9335 HGA 4 M9335 AUA 4 Control Type On Off Floating Proportional On Off Floating Power Requirements 24 VAC 20 6 1 VA running 24 VDC 10 2 1 W running Norminal AC 230 V at 50Hz 0 04 Transformer Sizing Requirements 7 VA Input Signal Adjustments 24 VAC 20 24 VDC 10 DC 0 2 to 10 V or 0 4 to 20 mA with field furnished 500 ohm 1 4 W resistor Offset DC 0...

Страница 10: ...trols com contact 1 844 820 4830 Triatek www triatek com contact 1 888 424 1922 1 770 242 1922 Region Group Contact information North America Product Sales Support jciorder jci com 1 800 275 5676 Option 1 Order Support Applied DX Sales Support applieddxsalessupport jci com Triatek Sales Support sales triatek com 1 888 424 1922 1 770 242 1922 Region Group Contact information North America Product T...

Отзывы: