background image

M300MJ-4-20 
4-20mA Analog Input Module

Before InstAllIng

This information is included as a quick reference installation guide. Refer to 
the control panel installation manual for detailed system information. If the 
modules will be installed in an existing operational system, inform the opera-
tor and local authority that the system will be temporarily out of service. Dis-
connect power to the control panel before installing the modules.

NOTICE: This manual should be left with the owner/user of this equipment.

generAl DescrIptIon

The  M300MJ-4-20  4-20mA  Analog  Input  Module  is  intended  for  use  in  in-
telligent, two-wire systems, where the individual address of each module is 
selected using the built-in rotary switches. This module allows intelligent pan-
els to interface and monitor two-wire or three-wire sensors, that produce a 
4-20mA signal output. It transmits the status (normal, open, or alarm) of one 
sensor  back  to  the  control  panel.  The  M300MJ-4-20  has  a  panel  controlled 
LED indicator. Only one sensor can be connected to the M300MJ-4-20.

coMpAtIBIlIty requIreMents

To  ensure  proper  operation,  this  module  shall  be  connected  to  a  compati-
ble Johnson Controls system control panel only (list available from Johnson 
Controls). In addition, please refer to Johnson Controls Device Compatibility 
document for the list of compatible devices.

fIgure 1. controls AnD InDIcAtors:

C0218-05

specIfIcAtIons

SLC

  Normal Operating Voltage: 

15 to 32 VDC

  Maximum Current Draw: 

9.3 mA (LED on)

  Average Operating Current: 

1 mA (LED flashing)

External Supply

  Normal Operating Voltage: 

24 VDC Nominal

  Standby Current: 

10 mA

  Maximum Current: 

510 mA

Initiating Device

  Maximum Current: 

500 mA

Temperature Range: 

–10°C to 60°C

Humidity: 

10% to 95% Non-condensing

Dimensions: 

4

1

/

2

˝ H × 4˝ W × 1

1

/

4

˝ D (Mounts to a 4˝ square by 2

1

/

8

˝ deep box.)

Accessories: 

SMB500 Electrical Box

JC-460-007 

I56-3369-001

I56-3369-00

1

InstAllAtIon AnD MAIntenAnce InstructIons

MountIng

The M300MJ-4-20 mounts directly to 4-inch square electrical boxes (see Fig-
ure 2). The box must have a minimum depth of 2

1

/

8

 inches. Surface mounted 

electrical boxes (SMB500) are available from Johnson Controls.

fIgure 2. MoDule MountIng:

C0449-01

WIrIng

NOTE:  All  wiring  must  conform  to  applicable  local  codes,  ordinances,  and 
regulations. This module is intended for powerlimited wiring only.

1.   Install module wiring in accordance with the job drawings and appropri-

ate wiring diagrams.

2.  Set the address on the module per job drawings.
3.  Secure module to electrical box (supplied by installer), Figure 2.

507 E. Michigan Street