SAFETY INSTRUCTIONS 

 

Please read these safety instructions carefully. 

 

1.  Keep this User Manual for future reference. 

 

2.  Power connectors should remain accessible for disconnection and be located 

where no-one can step on or trip over them. Disconnect the equipment from the 

alternating current (AC) output before cleaning. 

 

3.  The device must not be exposed to water or drips and no liquid-filled objects should 

be placed on top of it. Do not use liquid or powdered detergent for cleaning. Do not 

expose the device to moisture or damp areas. 

 

4.  No naked flame sources, such as lighted candles, should be placed on top of the 

device. 

  

5.  The device must be installed on a safe surface. If the device is not placed on a 

safe surface, it could fall and become damaged.  

 

6.  Never open the device. For safety reasons, the device should only be opened by 

qualified personnel.  

 

7.  Pay attention to the connection polarity when operating equipment with a direct 

current (DC) power supply. Reverse polarity connection may damage the 

equipment or power supply. 

 

8.  If any of the following situations occurs, please get technical personnel to check 

the device: 

a)  The power cord or plug is damaged. 

b)  Liquid has penetrated the inside of the device. 

c)  The device has been exposed to moisture. 

d)  The device does not work well or does not work according to the instruction 

manual. 

e)  The device has been dropped and damaged.  

f)  The device has obvious signs of damage. 

 

9.  Wiring must be undertaken only by qualified personnel. Ensure that the appropriate 

cables are used for the connections. 

 

 

 

 

 

 

Содержание LDATFL2S01

Страница 1: ...L 2 2019 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Tyco Fire Security GmbH Victor von Bruns Strasse 21 8212 Neuhausen am Rheinfall Switzerland ...

Страница 2: ...a safe surface If the device is not placed on a safe surface it could fall and become damaged 6 Never open the device For safety reasons the device should only be opened by qualified personnel 7 Pay attention to the connection polarity when operating equipment with a direct current DC power supply Reverse polarity connection may damage the equipment or power supply 8 If any of the following situat...

Страница 3: ...nual TFL2 3 Rev 0 3 1 Contents 1 DESCRIPTION 4 1 1 INPUTS 4 i SPEAKER LINE INPUTS 4 ii IMPEDANCE SELECTOR 4 2 CONNECTION AND COMMISIONING 5 3 TECHNICAL CHARACTERISTICS 6 4 List of Diagrams 6 5 List of Tables 6 ...

Страница 4: ...ere is a green connector to plug in the speaker line Mark Description Type Signals Activation Green Speaker line connection Input AB Pilot tone 19KHz Table 1 Speaker Line Input The connection is a Euroblock type connector with 2 contacts and 5 08mm width provided with the device The cable section range for each pole of the connector is 0 5 2 5mm2 22 12 AWG ii IMPEDANCE SELECTOR The end of line dev...

Страница 5: ... in line connected impedance is within the specified range using the ONE or NEO series devices If necessary change the switch position to modify the impedance value to 200R This may occur in very long or low power lines 10W Figure 2 End of Line Device Connections NOTE Do not connect the end of line device to the secondary side output of a volume controller This may result in the end of line device...

Страница 6: ...gr 1oz Dimensions A x H x P 66 3mm x 20mm x 50mm 2 61in x 0 79in x 1 97in Accessories Euroblock connector View and size mm Figure 3 View and Dimensions of the End of Line Device in mm 4 List of Diagrams Figure 1 End Of Line Device TFL 2 4 Figure 2 End of Line Device Connections 5 Figure 3 View and Dimensions of the End of Line Device in mm 6 5 List of Tables Table 1 Speaker Line Input 4 Table 2 Im...

Отзывы: