supply, HSM2204 output module, HSM2HOST9 2-way wireless transceiver, PG9901 indoor siren,
PG9911 outdoor siren, and 3G2080(R)E/ TL2803G(R)E/ TL280(R)E cellular and PSDN communication
module.
Caution
• For SIA FAR installations use only modules/devices that are listed on this page.
• Fire Alarm Verification feature (Auto Verified Fire Zone type [025]) is not supported on 2-wire
smoke detectors zones. This feature may be enabled for 4-wire smoke detectors only and
wireless detectors PG9936. The fire alarm delay is 60s.
• Call Waiting Cancel (Section [382], option 4) on a non-Call Waiting line will prevent successful
communication to the supervising station.
• All system smoke detectors must be tested annually by conducting an Installer Walk Test.
Prior to exiting Walk Test mode, a sensor reset must be done on the system, [*][7][2], to reset
all latching 4-wire smoke detectors. Refer to the installation instructions supplied with the
detector for details.
Notes
• Programming at installation may be subordinate to other UL requirements for the intended
application.
• Cross zones have the ability to individually protect the intended area (e.g. motion detectors
which overlap).
• Cross zoning is not recommended for line security Installations nor is it to be implemented on
exit/entry zones.
• This control panel has a communication delay of 30 seconds. It can be removed or increased
up to 45 seconds by the end user with installer consultation.
• The system shall be installed with the sounding device activated and the communicator
enabled for transmission using SIA or CID format.
• ULC commercial burglary installations require DEOL resistors.
SIA quick reference table
SIA Feature
Programming Section
Comments
Range/Default
Requirement
Exit Time
[005]>[001], option 3
Access to Entry and Exit
delays and Bell Time
Out for the system.
Range:45- 255 seconds
Default: 60 sec.
Required
(programmable)
Exit Delay Restart
[018], option 7
Opening a Delay
zone door after it has
already been opened
and closed during an
exit delay restarts the
exit delay timer.
Default: Enabled
Required