Figure 3: FEC1621 physical features
Table 1: FEC1621 physical features callouts and
descriptions
Physical feature: description and references
1
Binary Output (BO) Source Power Selection Jumpers (see
Binary Output (BO) source power selection jumpers
2
Device Address DIP Switch Block (see Figure 9)
3
Mounting Clip
4
Configurable Output (CO) Terminal Blocks (see Table 2)
5
24 VAC, Class 2 Supply Power Terminal Block (see Figure 6)
6
Cover Lift Tab (One of Two) (see Figure 3)
7
Display Navigation Buttons (see
Note:
Not available on all FEC models.
8
Setting up an integral or local
Note:
Not available on all FEC models.
9
FC Bus Terminal Block (see
10
Sensor Actuator (SA) Bus Terminal Block (see
11
Sensor Port (Sensor Actuator [SA] Bus, RJ-12 6-pin Modular
12
Binary Inputs (BIs) Terminal Block (see Table 2)
13
Universal Inputs (UIs) Terminal Blocks (see Table 2)
14
LED Status Indicators (see Table 8)
15
Field Controller (FC) Bus Port (RJ-12 6-pin Modular Jack)
(see Figure 6)
16
Binary Output (BO) Terminal Block (see Table 2)
Wiring
CAUTION
Risk of Electric Shock
Disconnect the power supply before making electrical
connections to avoid electric shock.
ATTENTION
Risque de décharge électrique
Débrancher l'alimentation avant de réaliser tout rac-
cordement électrique afin d'éviter tout risque de
décharge électrique.
CAUTION
Risk of Property Damage
Do not apply power to the system before checking all
wiring connections. Short circuited or improperly con-
nected wires may result in permanent damage to the
equipment.
ATTENTION
Risque de dégâts matériels
Ne pas mettre le système sous tension avant d'avoir
vérifié tous les raccords de câblage. Des fils for-
mant un court-circuit ou connectés de façon incor-
recte risquent d'endommager irrémédiablement
l'équipement.
Important:
Do not exceed the controller electrical
ratings. Exceeding controller electrical ratings can
result in permanent damage to the controller and
void any warranty.
Important:
Use copper conductors only. Make
all wiring in accordance with local, national, and
regional regulations.
Important:
Electrostatic discharge can damage
controller components. Use proper electrostatic
discharge precautions during installation, setup, and
servicing to avoid damaging the controller.
For detailed information on configuring and wiring
an MS/TP Bus, FC bus, and SA bus, refer to the
MS/TP
Communications Bus Technical Bulletin
(LIT-12011034)
. For
Metasys
System FEC1611 and FEC1621 Field Equipment Controller Installation Guide
3