INSTALLATION
INSTALLATION SAFETY INFORMATION
Read these instructions before continuing this appliance
installation. This is an outdoor combination heating and cool-
ing unit. The installer must assure that these instructions are
made available to the consumer and with instructions to
retain them for future reference.
1.
Refer to the furnace rating plate for the approved type of
gas for this furnace.
2.
Install this furnace only in a location and position as
specified on Page 9 of these instructions.
3.
Never test for gas leaks with an open flame. Use commer-
cially available soap solution made specifically for the
detection of leaks when checking all connections, as spec-
ified on Pages 7, 22, 23 and 38 of these instructions.
4.
Always install furnace to operate within the furnace's
intended temperature-rise range with the duct system
and within the allowable external static pressure range,
as specified on the unit name/rating plate, specified on
Page 40 of these instructions.
5.
This equipment is not to be used for temporary heating
of buildings or structures under construction.
PRECEDING INSTALLATION
1.
Remove the two screws holding the brackets in the front,
rear and compressor side fork-lift slots.
2.
Turn each bracket toward the ground and the protective
plywood covering will drop to the ground.
3.
Remove the condenser coil external protective covering
prior to operation.
4.
Remove the toolless doorknobs and instruction packet
prior to installation.
LIMITATIONS
These units must be installed in accordance with the following:
In U.S.A.:
1.
National Electrical Code, ANSI/NFPA No. 70 - Latest
Edition
FIRE OR EXPLOSION HAZARD
Failure to follow the safety warning exactly could
result in serious injury, death or property damage.
Never test for gas leaks with an open flame. use a
commercially available soap solution made specifi-
cally for the detection of leaks to check all connec-
tions. A fire or explosion may result causing property
damage, personal injury or loss of life.
FIGURE 1 -
UNIT SHIPPING BRACKET
Bracket
Screws
Turn down
FIGURE 2 -
COMPRESSOR SECTION
This product must be installed in strict compliance
with the enclosed installation instructions and any
applicable local, state and national codes including,
but not limited to, building, electrical, and mechani-
cal codes.
The furnace and its individual shut-off valve must be
disconnected from the gas supply piping system
during any pressure testing at pressures in excess
of 1/2 PSIG.
Pressures greater than 1/2 PSIG will cause gas
valve damage resulting in a hazardous condition. If it
is subjected to a pressure greater than 1/2 PSIG, the
gas valve must be replaced.
The furnace must be isolated from the gas supply
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas sup-
ply piping system at test pressures equal to or less
than 1/2 PSIG.