4
Installation and Maintenance
No.
Name
No.
Name
1
Indoor unit
8
Sealant
2
Outdoor unit
9
Wrapping tape
3
Connection pipe
10
Support of outdoor
unit
4
Drainage pipe
11
Fixing screw
5
Wall-mounting
frame
12
Drainage plug(cooling
and heating unit)
6
Connecting
cable(power cord)
13
Owner’s manual,
remote controller
7
Wall pipe
1. Safety Precaution
(1)
All
electric safety regulations
must be followed
when
installing
the unit.
(2)
U
se
proper
power supply circuit and air switch
in
accordance with local safety regulations.
(3)
The
power supply
must be sized to meet
the requirement
s
of air condition
ing unit
.
I
ncorrect
sizing/
wiring
may result in
electric shock,fire hazard or malfunction.
(4)
Properly connect the live wire, neutral wire and grounding
wire of power socket.
(5)
Be sure to cut off the
main
power supply before
performing
any
electrical work
.
(6)
Do not
turn
power back on until installation is complete
.
(7)
For appliances with type Y attachment,the instructions
shall contain the substance of thefollowing.If the supply cord is
damaged,
it must be replaced by the manufacturer,
its
service
agent or
a qualified technician to avoid any shock
hazards.
(8)
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper tube.
2
.
4
Installation
- Checking Parts
2
.
5
Selection of Installation Location
2
.
6
Electric Connection Requirement
2.7
Installation of Indoor Unit
Air-conditioner
Air switch capacity
09/12K
16A
18K
20A
24K
30A
1. Please contact the local agent for installation.
2. Don't use unqualified power cord.
1. Basic Requirement:
Installing the unit in the following places may cause
malfunction. If it is unavoidable, please consult the local dealer:
(1)
Areas
with strong heat sources, vapors, flammable or
explosive gas, or volatile objects spread in the air.
(2)
Areas
with high-frequency devices (such as welding
machine, medical equipment).
(3)
Areas
near coast.
(4)
Areas
with oil or fumes in the air.
(5)
Areas
with sulfureted gas.
(6) Other places with special circumstances.
2. Grounding Requirement
s
:
(1)
The air condition
ing unit
must
be properly ground
ed
with
a
specialized grounding device by a
certified technician
.
Please make sure it is always grounded effectively,
otherwise
it may cause electric shock.
(2)
The yellow-green wire in air conditioner is grounding wire,
which can't be used for other purposes.
(3)
The grounding resistance should comply with national
electric safety regulations.
(4)
The
unit
must be positioned so that the plug is
accessible.
(5) An all-pole disconnect switch having a contact separation
of at
least 1/8 inch in all poles should be connected in fixed
wiring.
(6)
Including an air switch with suitable capacity, please note
the
following table. Air switch should be included magnet
buckle and
heating buckle function, it can protect the circuitshort
and
overload. (Caution:
P
lease do not use
only the fuse to
protect the circuit
.
)
1. Choosing Installation Iocation
Recommend installation location to the client
based on field
conditions; then proceed after client approval.
2. Install Wall-mounting Frame
(1) Hang the wall-mounting frame on the wall; adjust it in
horizontal position with the level meter and then point out the
screw fixing holes on the wall.
(2) Drill the screw fixing holes on the wall with impact drill (the
specification of drill head should be the same as the plastic
expansion particle) and then fill the plastic expansion particles
2. Indoor Unit:
(1)
There should be no obstruction near air inlet and air outlet.
(2)
Select a location where the condensation water can be
dispersed easily and won't affect other people.
(3)
Select a location which is convenient to connect the
outdoor unit and near the power socket.
(4)
Select a location which is out of reach for children.
(5)
The location should be able to withstand the weight of
indoor unit and won't increase noise and vibration.
(6)
The appliance must be installed 98 3/7 inch above floor.
(7)
Don't install the indoor unit right above the electric
appliance.
(8)
The appliance
should not be installed in a laundry area
.
3. Outdoor Unit:
1.Select a location where the noise and outflow air emitted by
the outdoor unit will not affect neighborhood.
2.The location should be well ventilated and dry, in which the
outdoor unit won't be exposed directly to sunlight or strong
wind.
3.The location should be able to withstand the weight of
outdoor unit.
4.Make sure that the installation
complies with
r
equirement
s
i
of the i
nstallation dimension
s
diagram.
5.Select a location which is out of reach for children and far
away from animals or plants.If it is unavoidable, please add
fence for safety purpose
s
.
Note: