14
Technical Information
Service Manual
2.4 Communication malfunction
Detection of the quantity of installed indoor units:
After 3min of energizing, if the outdoor unit does not receive the communication data of
a particular
indoor unit, the outdoor
unit
will
judge that
the
indoor
unit is not installed
and the out door unit will give an error code
.
If
the outdoor unit receives the
communication
data of
that indoor unit later, the outdoor unit will treat that unit as
if
it is installed.
2.5 Overcurrent Protection
a.
Overcurrent protection of complete unit;
b.
P
hase wire current protection;
c.
C
ompressor phase
current protection
2.6 Compressor high-pressure protection
2.6.1 When the high-pressure
switch is detected
cut
off for 3s
continuously, the
compressor will enter high-pressure
protection
as it stops when reaching
set temperature. Meanwhile, the outdoor
unit will send
a
signal of “high-pressure
protection”
to
the
indoor units
(error code)
.
2.6.2 After the appearance of high-pressure
protection, when the high-pressure
switch is detected closed
for 6s
continuously, the compressor can resume running only after
the main power has been reset
.
2.7 Compressor overload protection
If the compressor overload switch
is detected
, the indoor unit will display the corresponding
error code
as it
stops. When the
compressor
stops for more than 3min and the compressor overload switch is reset, the unit will resume operation status
automatically. If the protection appears for more than
6 times (if the running time of the compressor is longer than 30min, the
protection times record will be cleared)
.
T
he unit can not resume operation
status automatically, but can resume running
only
after
resetting of the main
power.
2.8 Compressor
Phase Lock-out
Protection
When
the
compressor
starts,
if
one
of
the
three phases is detected open, the compressor will enter phase
lock-out
protection.
The
error code
will be cleared after 1min, the unit will restart and then detect if there is still phase
lock-out
protection. If the phase-lacking protection
is detected for 6 times continuously, the compressor
will not restart but can resume
running only
after
resetting of the main
power. If
the running time of the compressor
is longer than 7min, the protection
times record will be cleared.
2.9 IPM Protection
2.9.1 When
the I
PM
module protection is detected, the unit will stop, PFC is
closed, display
ing
IPM
protection
malfunction.
After
the
compressor
stops for
3min,
the
unit
will resume operation status
automatically
.
If
the
IPM
protection
is
detected for more than 6 times continuously (
i
f the running time of the compressor
is
longer
than 7min, the protection times
record will be cleared),
the system will stop and send the signal of module
protection to
the
indoor unit. The unit can not
resume operation status automatically
until the main power is reset.
2.9.2
IPM
module overheating protection
2.9.2.1 When T
I
PM
η
8
5
ć
,
prohibit to raise frequency
.
2.9.2.2 When T
I
PM
≥ 9 0
ć
,
the operation frequency of compressor
decreases
by
15% every 90s according to the present
capacity
requirement
of the complete
unit. It will keep 90s after
decreasing
the frequency.
After
decreasing
the frequency, if
T
IPM
≥ 9 0
ć
,
the unit will circulate the above movement until reaching the minimum frequency;
if 85
ćζ
T
IPM
ζ
9
0
ć
,
the
unit
will
run at this frequency
.
W
hen T
I
PM
≤ 8 5
ć
,
the unit will run at the frequency according to the capacity requirement
.
2.9.2.3 When T
I
PM
≥ 9 5
ć
,
the
compressor
stops.
After
the
compressor stops
for
3min,
if
T
IPM
ζ
8
5
ć
,
the
compressor and
the outdoor fan will resume operation.