![Johnson Controls DHMW09NCB21S Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/johnson-controls/dhmw09ncb21s/dhmw09ncb21s_owners-manual_2023304016.webp)
8
*
Either the right rear or right side of the unit is suitable for
securing
the
condensate
pipe.
*
The diameter of the
condensate
pipe should be equal to or greater than that of the
connecting pipe.
*
Make
the
condensate
pipe as short as possible and slope downward to prevent air
pockets.
(Refer to Fig.10
below.
)
*
Use the attached
condensate
hose
④
and clamp
⑤
.
*
Insert the
condensate
hose completely into the drain socket. Tighten the clamp within the
range of
gray tape until the screw head is less than
5/32 in. (
4mm
)
from the hose. (Refer to Fig.11,
Fig.12
below.
)
*
There should be no
folding of
the condensate
hose inside the indoor unit. (Refer to Fig.
12
.
)
(2).
Confirm that smooth drainage is achieved after the piping work.
Pour
20 oz. (
600cc
)
of water into the
condensate
pan from the air outlet
to confirm
proper
drainage.(Refer to Fig.1
3
.
)
(When
condensate
hose is connected)
Incl
ine
the drain hose
Not to be lifted
No folding
Not to be
laying
in water
Clamp
⑤
Condensate
hose
④
Taping area(Gray)
Fig.10
Fig.11
Water
container
Air outlet
Fig.1
2
Fig.1
3
3.5
Condensate
P
ipe Installation
Make sure the drain flows
smoothly
(1).
Condensate
piping.
Содержание DHMW09NCB21S