App/BOSS Username
is the same as the
Main
Receiver User Name
.
App/BOSS Password
If required, enter the Password
supplied by the operator that provides the GPRS service.
Default:
None.
+
App/BOSS Password
is the same as the
Main
Receiver Password
.
n
Cellular
This subgroup is for setting the GPRS connection for
telemonitoring with Sur-Gard SYSTEM
I
/
II
/
III
receivers.
3
In order to comply with EN50131 Grade 3 standards,
ONLY use the
ABS-IP
IP Module to report alarms: the
ABS-GSM
GSM/GPRS Module CANNOT be used.
+
Bearing in mind the delays which may occur in trans-
mission via GPRS, which are caused by the activities
of the network manager, we recommend you pro-
gram as many call attempts as possible, and that you
also provide a backup telephone number which
transmits alarms via GSM as well as via GPRS.
+
If you intend to use only one receiver, the primary
receiver options must be programmed.
Remote interruption of remote monitoring
!
The central station may decide to stop remote
monitoring without the need for end user con-
sent. In this case, the central station will no lon-
ger receive any events from the panel, even if
the GSM Module is enabled and properly
programmed.
The interruption of remote monitoring is reported with
the faults
Main Receiv.Lost
for the
Main Receiver
and
2nd Receiv. Lost
for the
Backup Receiver
.
These faults can also be triggered by other causes.
If the fault is due to the interruption of remote monitor-
ing, the event log will include the events
MainRec
OFF-CMS
for the
Main Receiver
and
2ndRec
OFF-CMS
for the
Backup Receiver
.
To reset remote monitoring, the central station must
re-enable the reception of events and:
Ø
the GSM Module must be first disabled then re-en-
abled using the specific command in the installer
menu (see “KEYPAD OPERATIONS > 3.4) View
GSM Module Status”) or in the user menu (see
“OPERATIONS FROM TOUCH KEYPAD > System
> GSM” or “OPERATIONS FROM LCD KEYPAD >
View > GSM Module Status (3.3)” in the User Man-
ual), or
Ø
the BOSS must send to the panel a program in which
at least one option of the
GSM
group has been modi-
fied.
DNIS
Enter the DNIS number (Dialed Number Identifi-
cation Service), if required.
Default:
None.
Fibro Account #
Enter the Customer Code for the
Fibro
15
protocol: ask the Central Station.
Default:
0000FFFFFF.
+
Ensure a different Customer Code is assigned to
each Control Panel that transmits events to the
same receiver.
Receiver Functionality Mode
Select the operating
mode of the receivers:
Ø
Primary and Backup
, the Backup Receiver will only
be used when communication fails on the Main re-
ceiver;
Ø
Redundant
, events will be sent to the Main and
Backup Receiver at the same time.
Default:
Primary and Backup.
+
If
Redundant
is selected, the
APN 2
,
APN 2
Username
and
APN Password
CANNOT modi-
fied and are copied by the
Main Receiver APN
, the
Main Receiver User Name
and the
Main Re-
ceiver Password
respectively.
Account #
Enter the Customer Code for the Contact
ID and SIA protocols: ask the Central Station.
Default:
0000.
Communication Protocol
Select the protocol speci-
fied by the Central Station:
Ø
SIA over FIBRO;
Ø
Contact ID over FIBRO.
Default:
Contact ID over FIBRO.
SIA Code for Panel Lost Event
Enter the SIA Event
code that must be sent when the GSM module cannot
communicate with the Control Panel.
Default:
00.
CID Code for Panel Lost Event
Enter the Contact ID
Event code that must be sent when the GSM module
cannot communicate with the Control Panel.
Default:
000.
Encryption Enabled
If enabled, communication with
the receiver will be encrypted with a variable key.
Default:
enabled.
3
In order to comply with the EN50131 Grade 3 stan-
dard, the option must be enabled.
GSM Network Fault Delay
Set how long the GSM net-
work must be faulty before a
GSM Link Lost
event is
triggered and a
GSM network
failure is reported. If the
GSM network is restored before the end of the pro-
grammed time, the event has NOT occurred and the fault
90
Expandable Hybrid Control Panel
15
To transmit events to IP receivers, the Contact ID and SIA protocols are encapsulated in the Fibro protocol and this
protocol requires its own Customer Code to identify the system transmitting the events.