The
Codes and Options
option group is to setup the user
PINs as follow.
Label
This option (maximum 16 characters) is to iden-
tify the User PIN in all the operations it is involved in
(e.g. User’s Name).
User Code
If the
PIN Transfer
option is disabled, the
masked PIN (a series of dots) appears.
If the option
PIN Transfer
is ENABLED, the PIN is dis-
played clearly: type the desired PIN or press the
but-
ton to have the BOSS generate a random one; enter all
“A” to disable the PIN.
Available
If this option is enabled, the PIN can be pro-
grammed and used for system access.
Many applications require fewer PINs. This option will
allow you to enable only the required number of PINs,
thus simplifying the programming process while in-
creasing the security level. PINs which have not been
made
Available
can be considered inexistent.
Active
If enabled, the PIN can perform the operations
for which it was programmed.
If disabled the PIN CANNOT access the system.
Default:
ONLY enabled for PIN no. 1.
+
This option is read-only. ONLY a Master User PIN
can change the status of this option (see “TOUCH
KEYPAD OPERATIONS > (User) Menu > PIN”,
“LCD KEYPAD OPERATIONS > PIN Programming
(2.5)”, “TELEPHONE OPERATIONS > Disable Cur-
rent User PIN (
9
) ”And “SMS OPERATIONS > Dis-
abling a PIN” in the USER MANUAL.
Keypad
If this option is enabled the User PIN can man-
age the system by keypad.
Hold-up
If this option is enabled, any Telephone ac-
tions (calls or reports) associated with the
Valid PIN
event (generated by the PIN concerned) will not be sig-
nalled on the LCD keypad ( will not appear over the
i
icon).
DTMF
If this option is enabled the User PIN can man-
age the system by touchtone telephone.
Default
: enabled for PINs from No. 2 to No. 10.
+
This option is NOT available for PIN N. 1.
SMS
If ENABLED, the PIN can control some events by
SMS (see “Events and Actions > Remote Command
Events”) and can Arm/Disarm the Partitions via SMS
(Grade 2 Control Panels ONLY).
Default
: enabled for PINs from No. 2 to No. 10.
+
This option is NOT available for PIN N. 1.
In And Group
If this option is ENABLED, the PIN may
be used to disable Partitions with the option
AND
Keys/Codes-Num
set to
2 Keys and/or Codes
or
3 Keys and/or Codes
(see
Partitions
option group).
Default:
enabled.
User type
This option is required for setting the opera-
tions that the User PIN can manage, as shown in Ta-
ble 20.
3
The
Super User
is available ONLY on Grade 3
Control Panels and must be enabled by a
Master
User
, as described in the USER MANUAL.
+
The Partitions disarmed with a
Patrol
PIN are auto-
matically re-armed after the Partition
Time-Patrol
(see
Partitions
Options Group).
e
In order to comply with the EN50131-1 and
EN50131-3 standards, the PIN n. 1’s
User Type
must be
Master
.
84
Expandable Hybrid Control Panel
Operations
Super
Master
Norm
al
Limited
Patrol
Global Arming
Yes Yes Yes Yes Yes
Special Arming
Yes Yes Yes Yes
NO
Disarming
Yes Yes Yes Yes Yes
Alarm View
Yes Yes Yes Yes Yes
Alarm Reset
Yes Yes Yes Yes
NO
Tamper View
Yes Yes Yes Yes Yes
Tamper Reset
Yes Yes*Yes*Yes*
NO
Fault View
Yes Yes Yes Yes Yes
Fault Reset
Yes Yes*Yes*Yes*
NO
Bypass View
Yes Yes Yes Yes Yes
Partition Status View
Yes Yes Yes Yes Yes
System Status View
Yes Yes Yes Yes Yes
Overtime Request
Yes Yes Yes
NO NO
Phone Call Cancellation
Yes Yes Yes Yes
NO
Remote Service Request
Yes Yes
NO NO NO
Alarm Test
Yes Yes Yes
NO NO
Output Activation
Yes Yes
SI NO NO
Individual Partition Arming
Yes Yes
NO NO NO
Zone Test
Yes Yes
NO NO NO
En./Disab. Answer Machine
Yes Yes
NO NO NO
En./Disab. Installer
Yes Yes
NO NO NO
En./Disab. Automatic Arming
Yes Yes
NO NO NO
Date/Time Setting
Yes Yes
NO NO NO
En./Disab. PIN
Yes Yes
NO NO NO
Phone Number Programming
Yes Yes
NO NO NO
Personal PIN Change
Yes Yes Yes
NO NO
Zone Bypass
Yes Yes
NO NO NO
En./Disab. Super User
**
NO
Yes
NO NO NO
Key Disable
Yes Yes
NO NO NO
Log View
Yes Yes Yes Yes
NO
Zone Status View
Yes Yes Yes Yes
NO
GSM Module Status View
Yes Yes Yes
NO NO
SMS View
Yes Yes Yes
NO NO
IP Module Status View
Yes Yes Yes
NO NO
ABSOLUTA info View
Yes Yes
NO NO NO
Table 20
Operation available to various types of user:
*)
operation NOT permitted with the Grade 3 Control Panels;
**)
operation ONLY available on Grade 3 Control Panels.