System Options
The System Option Group is to setup the options that
determine the operating mode of the system. You can
find the following Sub-Groups System Group.
n
General
Lock Installer Code
If this option is enabled, restoral
of the default settings WILL NOT default the PIN of In-
staller Code.
+
If the option
Lock Installer Code
is enabled, you
CAN’T perform the Hardware Default. In this way
ONLY the Installer (the person that know the In-
staller PIN) can perform the default restore via an
LCD
Keypad
(refer
to “Factory
Default” in
“KEYPAD OPERATION” section).
BOSS Access Code
Enter the Installer PIN.
Default:
0104 (00104 for Grade 3 Control Panels).
+
If the PIN entered in this option does not match with
the one programmed into the Control Panel, you
CAN’T download/upload the options.
User Code Length
Enter the number of digits required
for the PIN automatically generated by the control panel
when the
Auto PIN Generation
option is enabled (refer
to the relative option).
Valid entries:
4 (Grade 2 Control Panels ONLY), 5 or 6.
Default:
5.
+
If the option
Auto PIN Generation
is disabled, the
user can program an 4 (Grade 2 Control Panels
ONLY), 5 or 6 digits PIN.
+
If the
EN50136
option in the group
System Op-
tions
>
EN50131/EN50136
is enabled, ONLY
6-digit PINs can be set.
Auto PIN Generation
If this option is enabled, the
Control Panel generates a random PIN when the user
asks for a new PIN. If this option is disable, the user
can enter the required PIN when he asks for a new PIN.
Default:
enabled.
+
In order to comply with the EN50131-1 and
EN50131-3 standards, this option should be
ENABLED.
+
If the
EN50136
option in the group
System Op-
tions
>
EN50131/EN50136
is enabled, this option
is enabled and CANNOT be disabled.
Clear System Call/SMS/Receiver actions by
Master Code
If disabled (default), the Main User PIN’s
can delete ONLY calls generated by Partition events
from the telephone queue.
If ENABLED, the Main User PIN’s may ALSO delete
calls generated by System Events from the telephone
queue.
Clear Call/SMS/Receiver actions on Disarming
by Master Code
If ENABLED, disarming with a Main
User PIN automatically cancels calls from the tele-
phone queue.
Default:
disabled.
+
Depending on the status of the
Clear System
Call/SMS/Receiver actions by Master Code
op-
tion, ONLY calls generated by Partiton Events and
ALSO those generated by System Events will be
deleted.
Enable Level 4
If this option is enabled, it is possible to
access Level 4 from a keypad connected to the Control
Panel (see “KEYPAD OPERATIONS”).
Default:
disabled.
Allow installer access to personal programming
Shows whether the installer is allowed to upload/down-
load the user’s PIN’s onto/from BOSS and a USB key
(read
“OPERATING
YOUR
SYSTEM
FROM
A
KEYPAD>Enable Installer (Teleservice) (2.2)” in the
USER MANUAL).
+
This is a read-only option.
Disable code if duplicated PIN
If the
Auto PIN Gen-
eration
option is disabled it may transpire that when a
new PIN is programmed it is the same as another PIN in
the system; in this case system security will be compro-
mised.
If this option is ENABLED the used PIN is disabled and
can only be re-enabled by a Master PIN enabled in the
same Partitions as the used PIN.
The duplicated PIN is flagged by:
Ø
the
Duplicated PIN
fault;
Ø
the
Duplicated and Discovered PIN
event.
+
The used PIN and the PIN which detected it are
stored in the events log.
+
This option is disabled and locked if the
Auto PIN
Generation
option is ENABLED.
Default:
disabled.
T1 Input or Output
Select the functioning mode for
terminal
T1
on Main Board:
Input
or
Output
.
Default:
Input.
T2 Input or Output
Select the functioning mode for
terminal
T2
on Main Board:
Input
or
Output
.
Default:
Input.
T3 Input or Output
Select the functioning mode for
terminal
T3
on Main Board:
Input
or
Output
.
Default:
Input.
T4 Input or Output
Select the functioning mode for
terminal
T4
on Main Board:
Input
or
Output
.
Default:
Input.
ABSOLUTA Plus