Device ID
In the
Device ID
option, enter the ID number
that you find on the wireless device: if a valid ID number
is entered, the console shows the corresponding type of
wireless device, and the options that you can set for that
type of device. Set the wireless device options as indi-
cated in “Wireless device options” on page 128.
Enter all zeros to remove a wireless device.
Valid Values:
three digits for the device type, and four
digits for the serial number.
Default:
000-0000.
Partitions
Double click the plus [+] icon to expand the
view, and select the siren’s partitions. The siren repeats
the acoustic signals relating to the selected partitions:
entry delay, exit delay, squawk, etc.
Default:
the siren is enabled on partition 1.
Alarm Masks
Select the sounds that the siren can
emit:
Ø
Burglary Alarm
: continuous sound
Ø
Fire Alarm
: three half-second sounds every 1.5 sec-
onds
Ø
Gas/CO Alarm
: four short sounds (0.1 seconds) ev-
ery ten seconds
Ø
Flood Alarm
: a sound of one second every three sec-
onds
Default:
Burglary Alarm
,
Fire Alarm
,
Gas/CO Alarm
,
and
Flood Alarm
.
In the
Outputs
options group, each sound of the wire-
less sirens can be associated with a logical output
(mapping of the outputs).
The control panel is able to detect and signal the follow-
ing events relating to wireless sirens:
Ø
Low batter: when the siren battery needs to be re-
placed;
Ø
Device lost: when the supervision time has expired
since the last siren communication;
Ø
Tamper
n
Wireless Repeaters
The
Wireless Repeaters
option group is for repeater en-
rolling, as described below.
#
In the column #, choose a free position to enroll the
wireless device.
Device ID
In the
Device ID
option, enter the ID number
that you find on the wireless device.
Enter all zeros to remove a wireless device.
Valid Values:
three digits for the device type, and four
digits for the serial number.
Default:
000-0000.
ABSOLUTA Plus
PROGRAMMING FROM THE PC
47
Logger
Description
WHO
Events and Actions
WLS rec. lost
N/A
System > WLS receiver lost
WLS rec. tamper
N/A
System > Wireless Receiver Tamper
WLS rec. tamper
N/A
System > Wireless Receiver Tamper
WLS Det. Fault
Zone Label
System > System Fault
WLS rep. bat.low
Device ID
System > System Fault
WLS rep. AC trbl
Device ID
System > System Fault
WLS Rep. Fault
Device ID
System > System Fault
WLS rep. tamper
Device ID
System > General System Tamper
WLS rep. lost
Device ID
System > General System Tamper
WLS sir. bat.low
Siren Label
System > System Fault
WLS Sir. Fault
Siren Label
System > System Fault
WLS siren tamper
Siren Label
System > General System Tamper
WLS siren lost
Siren Label
System > General System Tamper
WLS Key Fault
Keyfob Label
System > System Fault
... the keypad, in viewing signals mode, shows the message indicated in the
Message
column; the logger shows the
description indicated in the Description column, and detail of the device that caused the event, as indicated in the
WHO
column. N/A = Not Applicable.
Содержание Bentel Security tyco ABS128M50