Johnson Controls ASG-TP50FCS Скачать руководство пользователя страница 7

7.  Maintenance and Servicing

Even if during the warranty period, the snow protection hood becomes rusted under conditions that are 
caused by alkaline or corrosive moisture, it is recommended to provide salt damage resistance products to 
prevent such damage. 

,QRUGHUWRSURORQJWKHSURGXFWOLIHSHUIRUPSHULRGLFDOPDLQWHQDQFHWRSUHYHQWVLJQL¿FDQWDJLQJGXHWR

deterioration. Perform the following tasks as part of routine preventative maintenance for the equipment.

(1)  Red Rust Generation Check 

,IUHGUXVWLVJHQHUDWHGVFRXUWKHUXVWRႇ

(2)  Retighten installation and assembly screws. 

Check for loose screws and retighten when inspection and maintenance is performed. In order to 

SUHYHQWVFUHZEUHDNDJHEHVXUHWRWLJKWHQWRWKHIROORZLQJWRUTXHVSHFL¿FDWLRQV

 

* M5 Tapping Screw Type C for Assembling 

8

: 2.6 + 0.7 [Ibf-ft] (3.5 + 1.0 [N•m]) 

* M5 Tapping Screw Type B for Fixing Top Plate: 1.8 + 0.7 [Ibf-ft] (2.5 + 1.0 [N•m])

7

Содержание ASG-TP50FCS

Страница 1: ...the air outlet If the air blown out of the snow protection hood is sucked into the other outdoor unit it may cause a malfunction of the unit 5 Double check the strength of the anchor bolts of the out...

Страница 2: ...RQJ ZLQG 3URWHFW WKH VFUHZV DQG WKH VQRZ SURWHFWLRQ KRRG IURP VFUDWFKHV RU VFUDSHV WKDW PD FDXVH UXVW Handle with care the snow protection hood during assembly and installation SSO WRXFK XS FRDWLQJ RU...

Страница 3: ...ht Side Plate 1 2 Left Side Plate 1 3 Faceplate 1 2 4 Faceplate 2 2 5 Faceplate 3 2 6 Center Support 1 7 Horizontal Plate 2 8 Screw for Assembling M5 x 9 16L 14L tapping screw type C 42 2 Used for ass...

Страница 4: ...upport 6 together two places by using the assembly screws 8 3 Secure the faceplate 2 4 then faceplate 1 3 with the left side plate 2 and the assembled parts in step 2 together by using the assembly sc...

Страница 5: ...top plate then secure the faceplate 3 5 two pieces and horizontal plate 7 two pieces to the outdoor unit and the snow protection hood for air outlet with those removed screws and assembly screws 8 Sn...

Страница 6: ...Protection Hood Option 63 7 16 1611 63 1600 30 1 8 765 30 1 8 765 Available Combinations Applicable Outdoor Unit Representative Model Model H Y VAH P R 168 192B32S H Y VAH P R 168 192B42S H Y VAH P R...

Страница 7: ...LQJ GXH WR deterioration Perform the following tasks as part of routine preventative maintenance for the equipment 1 Red Rust Generation Check I UHG UXVW LV JHQHUDWHG VFRXU WKH UXVW R 2 Retighten inst...

Страница 8: ...2017 Hitachi Johnson Controls Air Conditioning Inc Code No LIT 12012438 Revised January 2020 P5416962 rev 2...

Отзывы: