TABLE 1
ELECTRICAL AND PHYSICAL DATA – 13 SEER
2.4 ELECTRICAL & PHYSICAL DATA (SEE TABLE 1)
MATCH ALL COMPONENTS:
• OUTDOOR UNIT
• INDOOR COIL/METERING DEVICE
• INDOOR AIR HANDLER/FURNACE
• REFRIGERANT LINES
3.0 LOCATING UNIT
3.1 CORROSIVE ENVIRONMENT
The metal parts of this unit may be subject to rust or deterioration if exposed to a
corrosive environment. This oxidation could shorten the equipment’s useful life.
Corrosive elements include, but are not limited to, salt spray, fog or mist in seacoast
areas, sulphur or chlorine from lawn watering systems, and various chemical conta-
minants from industries such as paper mills and petroleum refineries.
If the unit is to be installed in an area where contaminants are likely to be a prob-
lem, special attention should be given to the equipment location and exposure.
•
Avoid having lawn sprinkler heads spray directly on the unit cabinet.
•
In coastal areas, locate the unit on the side of the building away from the water-
front.
•
Shielding provided by a fence or shrubs may give some protection, but cannot
violate minimum airflow and service access clearances.
•
Elevating the unit off its slab or base enough to allow air circulation will help
avoid holding water against the basepan.
Regular maintenance will reduce the build-up of contaminants and help to protect
the unit’s finish.
Electrical
Physical
Model
Number
14AJM
Phase
Frequency (Hz)
Voltage (Volts)
Rated Load
Amperes
(RLA)
Compressor
Locked Rotor
Amperes
(LRA)
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM
[L/s]
Refrig.
Per
Circuit
Oz. [g]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Fuse or HACR
Circuit Breaker
Outdoor Coil
Weight
Rev. 4/28/2009
18
1-60-208/230
9/9
48
0.8
12/12
15/15
20/20
16.39
1
2805
112
154
171
[1.52]
[1324]
[3175]
[69.8]
[77.6]
24
1-60-208/230
13.5/13.5
58.3
0.8
18/18
25/25
30/30
16.39
1
2805
105.6
154
171
[1.52]
[1324]
[2994]
[69.8]
[77.6]
30
1-60-208/230
12.8/12.8
64
0.8
17/17
25/25
25/25
16.39
1
3000
112
157
175
[1.52]
[1416]
[3175]
[71.2]
[79.4]
36
1-60-208/230
16.7/16.7
79
0.8
22/22
30/30
35/35
21.85
1
3570
130.4
181
201
[2.03]
[1685]
[3697]
[82.1]
[91.2]
42
1-60-208/230
17.9/17.9
112
2.8
26/26
30/30
40/40
21.85
1
3060
145.12
205
225
[2.03]
[1444]
[4114]
[92.9]
[102.1]
48
1-60-208/230
21.8/21.8
117
2.8
31/31
40/40
50/50
21.85
2
4105
216
246
269
[2.03]
[1937]
[6124]
[112.9]
[122]
60
1-60-208/230
26.4/26.4
134
2.8
36/36
45/45
60/60
21.85
2
4105
240
254
274
[2.03]
[1937]
[6804]
[115.2]
[124.3]
ELECTRICAL AND PHYSICAL DATA – 14.5 SEER
NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set.
Electrical
Physical
Model
Number
Phase
Frequency (Hz)
Voltage (Volts)
Rated Load
Amperes
(RLA)
Compressor
Locked Rotor
Amperes
(LRA)
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM
[L/s]
Refrig.
Per
Circuit
Oz. [g]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Fuse or HACR
Circuit Breaker
Outdoor Coil
Weight
Rev. 6/2/2009
18
1-60-208/230
9/9
48
0.6
12/12
15/15
20/20
8.43
1
1675
75.2
120
128
[0.78]
[790]
[2132]
[54.4]
[58.1]
24
1-60-208/230
13.5/13.5
58.3
0.6
18/18
25/25
30/30
8.43
1
1665
73.8
121
129
[0.78]
[786]
[2092]
[54.9]
[58.5]
30
1-60-208/230
12.8/12.8
73
0.6
17/17
20/20
25/25
10.29
1
2075
86.08
135
143
[0.96]
[979]
[2440]
[61.2]
[64.9]
36
1-60-208/230
16.7/16.7
79
0.8
22/22
30/30
35/35
12.43
1
2690
96
159
167
[1.15]
[1269]
[2722]
[72.1]
[75.8]
42
1-60-208/230
17.9/17.9
112
0.8
24/24
30/30
40/40
16.39
1
2980
126.4
218
230
[1.52]
[1406]
[3583]
[98.9]
[104.3]
48
1-60-208/230
21.8/21.8
117
0.8
29/29
35/35
45/45
21.85
1
3175
144
225
237
[2.03]
[1498]
[4082]
[102.1]
[107.5]
60
1-60-208/230
26.4/26.4
134
1.2
35/35
45/45
60/60
21.85
1
3570
176
223
234
[2.03]
[1685]
[4990]
[101.2]
[106.1]