the current building regulations should
be used. Installation should be carried
out generally as shown on the following
diagram.
2.1.3 Gas connection
The gas supply to this appliance must
be installed in accordance with BS
6891 (1988).
Fit the 1/2" gas supply cock supplied
with this unit immediately before the
gas control block. No heat or soldered
joints should be applied in the vicinity
of the gas control block, as they could
cause damage to the control.
All connections and joints should be
tested for gas soundness with a
suitable leak detector (do not use a
naked flame).
2.1.4 Flue-gas exhaust and air
supply
The flue-gas exhaust and the air
supply must be installed according to
the tables.
Exterior-wall duct
(see Fig. 4).
Type: M2000 MDV80
Wl = 600
Piping material: thick/thin-walled
aluminium with lip-ring sealing.
Pipe diameter: Ø 80 mm.
Bend: 90°
SGT 30 / SGT 40
Size
Minimum
Maximum
A
500
1400
B
0
1000
All sizes are in mm.
Note: the fall of the horizontal piping to
the device should be at least 5 mm per
metre of pipe!
Fig. 4 – Size exterior-wall duct
IMD 0016
Содержание SGT 30 G