8. BOILER 

OVERHEATING

 

In the event of the boiler overheating the boiler will lockout and 
an error code will be displayed in the series of LED’s as detailed 
below. Turning the central heating water temperature control P1 to 
the OFF position and then back on again will clear the error and 
enable the boiler to relight.

 

If the fault recurs, turn off the boiler and consult a CORGI 
registered installer. 

9. CONDENSATE 

DRAIN

 

The condensate drain must not be modified or blocked.

 

Blockage of the condensate drain caused by debris or freezing, 
can cause the boiler to lockout.

 

If freezing is suspected and the pipe run is accessible, then 
an attempt to free the obstruction by pouring hot water on to 
the pipe may be made. If this fails to remedy the problem, the 
assistance of a CORGI registered installer should be sought.

10.  SERVICE & MAINTENANCE

 

It is recommended that a full maintenance check be carried out 
annually on the appliance. It is also recommended to take out a 
further service agreement on the expiry of the guarantee period.

 

You can obtain further information on this from your gas supplier.

 

The appliance should be checked /serviced by a CORGI 
registered installer. 

 

If you require service on your appliance please contact your local 
installer or gas supplier.

 

On completion of the service the installer should fill in the service 
section at the rear of the BENCHMARK log book. All installers 
registered with CORGI carry an identification card. This card will 
have an ID number which should be recorded in your logbook.

 

If you have any queries regarding your installer you can contact 
CORGI by telephone on 01256 372400.

11.  ESCAPE OF GAS

 

Should a gas leak be suspected contact your gas supplier with 
out delay.

 

Do not search for leak with a naked flame.

12.  CLEANING THE APPLIANCE

 

The appliance casing should only be cleaned with a damp cloth 
then dried. 

 

Do not use abrasive or solvent cleaners.

www.johnsonandstarley.co.uk

6

Содержание Reno HE16H

Страница 1: ...savingtrust org uk The Johnson Starley Reno range has an energy rating A on a scale of A to G For more information see www boilers org uk This is a certification mark www johnsonandstarley co uk USERS...

Страница 2: ...nstructions by competent persons and that it meets the requirements of the appropriate Building Regulations The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and...

Страница 3: ...he User Panel 4 3 Initial Lighting 5 4 Operation of Boiler 5 5 Reset Function 5 6 Error Codes 5 7 Flame Loss 5 8 Boiler Overheating 6 9 Condensate Drain 6 10 Servicing Maintenance 6 11 Escape of Gas 6...

Страница 4: ...ppliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instr...

Страница 5: ...nob P1 fully anti clockwise to the off position In this position the frost protection will still be active 5 RESET FUNCTION Should a fault occur tuRning the central heating water temperature control k...

Страница 6: ...full maintenance check be carried out annually on the appliance It is also recommended to take out a further service agreement on the expiry of the guarantee period You can obtain further information...

Страница 7: ...13 NOTES 7 Telephone 01604 762881...

Страница 8: ...Building Regulations HOME COMFORT SOLUTIONS Company Details Website Address www johnsonandstarley co uk Email sales johnsonandstarley co uk marketing johnsonandstarley co uk Telephone Number 01604 76...

Отзывы: