LOSS OF SYSTEM WATER PRESSURE

 

The pressure gauge indicates the central heating system pressure. If the pressure is seen to fall below the 
original installation pressure of 1-2 bar over a period of time then a water leak may be indicated. In this event 
conduct the re-pressurising procedure as shown. If unable to do so or if the pressure continues to drop a 
Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be consulted.

 

The boiler will not operate if the pressure has reduced to less than 0.3 Bar under this condition.

 

1. Ensure filling loop isolation valves are closed.

 

2. Remove the two caps

 

3. Attach on the filling loop.

 

4. Turn the filling loop isolation valves to the open position. The system will now fill.

 

5. Wait for pressure gauge dial to reach 1 to 1.5 bar.

 

6. Close the filling loop isolation valves.

 

7. Disconnect the filling loop at left hand side and angle upwards.

 

8. Attach the two caps as shown on point 2.

6.6 

CONDENSATE DRAIN

 

The condensate drain must not be modified or blocked.

 

Blockage of the condensate drain, caused by debris or freezing, can cause automatic shutdown of the 
boiler.

 

If freezing is suspected and the pipe run is accessible an attempt may be made to free the obstruction by 
pouring hot water over the exposed pipe and clearing any blockage  from the end of the pipe. If this fails to 
remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer 
(RGII) should be sought.

7.  

RESET BOILER

 

Press the reset button “K4” twice.

8.  

SERVICING & MAINTENANCE

 

It is recommended that a full maintenance check be carried out annually on the appliance. It is also 
recommended to take out a further service agreement on the expiry of the guarantee period.

 

You can obtain further information on this from your gas supplier.

 

The appliance should be checked /serviced by a GAS SAFE registered 
installer. 

 

If you require service on your appliance please contact your local installer or 
gas supplier.

 

On completion of the service the installer should fill in the service section at the rear of the BENCHMARK  
checklist. All installers registered with GAS SAFE carry an identification card. This card will have an ID 
number which should be recorded.

 

If you have any queries regarding your installer you can contact GAS SAFE by telephone on 0800 408 5500.

 

The appliance should be serviced at least once a year by a Gas Safe Registered Engineer or in IE a 
Registered Gas Installer (RGII).

9.  

CLEANING

 

For normal cleaning simply dust with a dry cloth.

 

To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth.

 

DO NOT use abrasive cleaning materials.

10.   ESCAPE OF GAS

 

Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay. 
Telephone 0800 111 999

 

Do NOT search for gas leaks with a naked flame.

Содержание Quantec 24S

Страница 1: ...s under one roof H E AT I N G H O T W AT E R V E N T I L AT I O N USER S INSTRUCTIONS QUANTEC SYSTEM ErP High Efficiency Boiler These instructions are to be left with the User Publication No ZZ 1435 5...

Страница 2: ...e customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance The service engine...

Страница 3: ...your guarantee return the guarantee card to Johnson Starley Ltd This will register the appliance and activate the guarantee 2 3 Ensure the appliance is serviced annually as failure to do so will inval...

Страница 4: ...Optional LCD DISPLAY CENTRAL HEATING TEMPERATURE FUNCTION MODES RESET BUTTON INSTALLER MODE K7 K1 K6 K2 K3 K5 K4 ITEM DESCRIPTION K1 CH Central Heating K2 CH Central Heating K3 Installer information K...

Страница 5: ...ate flow temperatures for the boiler thermostat settings are 6 2 DISPLAY CODES In normal operation the boiler status display will show codes 1 Standby no demand for heat 2 CH being supplied 3 Boiler f...

Страница 6: ...e from the end of the pipe If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII should be sought 7 RESET BOILER Press the reset...

Страница 7: ...t installer E08 Flame circuit failure Contact installer E09 Valve feed back ERROR Contact installer E12 EEPROM lockout Contact installer E15 Sensor drift lockout Fill system to 1 0bar Bleed radiators...

Страница 8: ...ss Reset Contact installer F37 Low water pressure Fill system to 1 0bar Bleed radiators Check radiator valves are open Reset boiler Contact installer F40 Water pressure too high Check to see if the ga...

Страница 9: ...ECHNICAL DATA FICHE Ecodesigns energy related products directive requires our appliance to be fully compliant with the ErP regulations Our unit has a label which shows the level of efficiency for the...

Страница 10: ...rking properly it helps keep you and your family safe If you re a tenant your landlord must arrange this every 12 months and provide you with a Landlord s Gas Safety Record You can set a free reminder...

Страница 11: ...e fuel bills Here are a few ways which can help you make those savings WATER SAVINGS 1 Fit a water saving shower head to save energy 2 Turn down the temperature on your washing machine and only do a f...

Страница 12: ...ales johnsonandstarley co uk marketing johnsonandstarley co uk Reception Customer Service 01604 762881 Fax 01604 767408 Anniversary 1922 2012 In the interest of continuous developement Johnson Starley...

Отзывы: