background image

3

Sales/Spares 01604 707012   Replacement Help Line 01604 707011

1.  

GENERAL INFORMATION

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT: IT IS A STATUTORY REQUIREMENT THAT ALL GAS APPLIANCES BE 

INSTALLED BY COMPETENT PERSONS, (i.e. GAS SAFE REGISTERED INSTALLERS. 

GAS SAFE MEMBERSHIP ENQUIRIES - TEL: 0800 408 5500) IN ACCORDANCE WITH 

THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS (CURRENT EDITION). 

FAILURE TO COMPLY WITH THESE REGULATIONS MAY RESULT IN PROSECUTION.

1.1 

Part of the installation and commissioning of this appliance is related to instructions for use by the heating 
engineer to the user where specific requirements may occur.

1.2 

The QuanTec Regular Kompact is a wall mounted, room sealed, condensing boiler, featuring full sequence 
automatic spark ignition and fan assisted combustion. Due to the high efficiency of the boiler, condensate 
is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe 
at the base of the boiler. A condensate ‘plume’ will also be visible at the flue terminal.

2.  

THE BOILER CONTROL PANEL

FIGURE 2. LCD DISPLAY FUNCTIONS

K7

K1

K6

K2

K3

K5

K4

Item

Description

K1

CH - Central H

K2

CH - Central Heating -

K3

Installer information

K4

Reset

K5

Summer/Winter mode

K6

Installer function only

K7

Installer function only

Содержание Quantec 16RK

Страница 1: ...y co uk USER S INSTRUCTIONS These instructions are to be left with the User Publication No ZZ 1464 September 2013 QUANTEC REGULAR Kompact High Efficiency Boiler Quantec 16RK G C No 41 416 19 Quantec 2...

Страница 2: ...e that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have re...

Страница 3: ...ions for use by the heating engineer to the user where specific requirements may occur 1 2 The QuanTec Regular Kompact is a wall mounted room sealed condensing boiler featuring full sequence automatic...

Страница 4: ...upplying heat to the central heating if required NOTE In normal operation the boiler status disply will be DISPLAY CODES Call for heat Burner on low Medium High Temperature of supply 4 OPERATING FUNCT...

Страница 5: ...he pipe If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII should be sought 5 RESET BOILER Press the reset button See Table 1...

Страница 6: ...ler E09 valve feed back ERROR Contact installer E12 EEPROM lockout Contact installer E15 Sensor drift lockout Ensure water in heating system Bleed radiators check system pressure Check valves are open...

Страница 7: ...valves are open Wait 15 minuets turn power OFF ON Contact installer F13 Remote Reset Lockout Turn power OFF and ON Press Reset Contact Boiler F53 Flue Temperature Sensor error Contact installer GAS LE...

Страница 8: ...es johnsonandstarley co uk marketing johnsonandstarley co uk Reception 01604 762881 Sales Spares 01604 707012 Service Warm air upgrade 01604 762881 Warm air upgrade 01604 707011 Johnson Starley Dravo...

Отзывы: