12.  ENERGY RATING ErP TECHNICAL DATA FICHE

Ecodesigns energy related products directive requires our appliance to be fully compliant with 
the ErP regulations. Our unit has a label which shows the level of efficiency for the boiler, CO

2

 & 

NOx emissions and db noise emissions. This will help the householder understand the energy 
efficiency within the home and help reduce energy consumption.
This regulation covers all products used in the installation. Once an installation has 
been completed the installer will supply a final label incorporating all the items used in 
the install. It shows the details of the systems overall efficiency. For further information 
about the ErP Directive visit the Johnson and Starley Ltd website or email our helpline on 
[email protected]

EU Regulations No. 811/2013 and No. 812/2013 supplementing Directive 2010/30/EU. 

TABLE 1.          ErP TECHNICAL DATA

HR28C HR28CP

30C 30C-SA 24C

PRODUCT DATA

SYMBOL

VALUE

VALUE

VALUE

VALUE

VALUE

UNIT

Condensing boiler

-

Yes

Yes

Yes

-

Low temperature boiler

-

No

No

No

-

B11 Boiler

-

No

No

No

-

Cogeneration space heater

-

No

No

No

-

Combination Heater

-

Yes

Yes

Yes

-

Rated heat output

P

rated

21

23

16

kW

Seasonal space heating energy efficiency

Ŋ

S

94

94

94

%

Energy efficiency class

-

A

-

USEFUL HEAT OUTPUT

At rated heat output and high temperature regime

P

4

21.4

23.4

16.3

kW

At 30% of rated heat output and low temperature regime

P

1

7.3

7.8

5.5

kW

USEFUL EFFICIENCY

At rated heat output and high temperature regime

Ŋ

4

87.9

87.9

88.8

%

At 30% of rated heat output and low temperature regime

Ŋ

1

98.8

99.1

98.9

%

AUXILLARY ELECTRICITY CONSUMPTION

At full load

el

max

0.068

kW

At part load

el

min

0.048

kW

In standby mode

P

SB

0.002

kW

OTHER ITEMS

Standby heat loss

P

SB

0.099

kW

Ignition burner power consumption

P

ign

0

kW

Sound power level indoors

L

WA

45

dB

ADDITIONAL DATA FOR COMBINATION HEATERS

Declared load profile

XL

M

XL

M

Daily electricity consumption

Q

elec

0.112

0.069

0.109

0.114

kWh

Annual electricity consumption

AEC

24

15

24

25

kWh

Daily fuel consumption

Q

fuel

21.03

6.98

22.59

7.65

kWh

Annual fuel consumption

AFC

16.7

427

17.89

6.06

Gj

Water heating energy efficiency

Ŋ

wk

91.4

85

86.5

78

%

Water heating energy efficiency class

-

A

-

1.     High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater output.
2.      Low temperature means for condensing boiler 30°C, for low temperature boilers 37°C and for other heaters 50°C return 

temperature (at heater).

Содержание 47-416-11

Страница 1: ...S INSTRUCTIONS QUANTEC HR PErP COMBI SAErP High Efficiency These instructions are to be left with the User Publication No ZZ 1431 5 February 2016 Quantec HR28C ErP G C No 47 416 11 Quantec HR28CP ErP...

Страница 2: ...ould on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance The service engineer should complet...

Страница 3: ...functions of the boiler If unsure ask the installer to explain 2 2 YOUR GUARANTEE To activate your guarantee return the guarantee card to Johnson Starley Ltd This will register the appliance and acti...

Страница 4: ...MESTIC HOT WATER TEMPERATURE LCD DISPLAY CENTRAL HEATING TEMPERATURE FUNCTION MODES RESET BUTTON INSTALLER MODE K7 K1 K6 K2 K3 K5 K4 ITEM DESCRIPTION K1 CH Central Heating K2 CH Central Heating K3 Ins...

Страница 5: ...l for central heating the boiler will fire for 1 minute at low and then will increase the modulation to match the demand for heating The display will show the flame symbol water temperature and flashi...

Страница 6: ...aring any blockage from the end of the pipe If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII should be sought 7 RESET THE B...

Страница 7: ...e circuit failure Contact installer E09 Valve feed back ERROR Contact installer E12 EEPROM lockout Contact installer E15 Sensor drift lockout Fill system to 1 0bar Bleed radiators Check valves are ope...

Страница 8: ...s Check radiator valves are open Reset boiler Contact installer F40 Water pressure too high Check to see if the gauge is over 2 8bar Bleed radiators Reset boiler Contact installer F47 Water pressure s...

Страница 9: ...ombination Heater Yes Yes Yes Rated heat output Prated 21 23 16 kW Seasonal space heating energy efficiency S 94 94 94 Energy efficiency class A USEFUL HEAT OUTPUT At rated heat output and high temper...

Страница 10: ...rking properly it helps keep you and your family safe If you re a tenant your landlord must arrange this every 12 months and provide you with a Landlord s Gas Safety Record You can set a free reminder...

Страница 11: ...e fuel bills Here are a few ways which can help you make those savings WATER SAVINGS 1 Fit a water saving shower head to save energy 2 Turn down the temperature on your washing machine and only do a f...

Страница 12: ...sales johnsonandstarley co uk marketing johnsonandstarley co uk Reception Customer Service 01604 762881 Fax 01604 767408 Anniversary 1922 2012 In the interest of continuous development Johnson Starley...

Отзывы: