User Guide
JV
3004
8
7. Periodic Maintenance:
Use compressed air or a vacuum to remove lint and debris from the motor, screen or
blower.
Do not wet the motor or the wiring. Do not use a pressure washer to clean the unit.
8. Troubleshooting:
ELECTRICAL SYSTEM
PROBLEM
POSSIBLE CAUSE
Does not tum on
1. Switch is defective.
2. Wall circuit breaker is tripped.
3. Defective power cord.
4. Capacitor is defective.
Does not operate at all speed
1. Switch is defective.
2. Capacitor is defective.
Blower wheel rubs
1. Wheel is out of round.
Unit makes abnormal sounds
1. Defective motor.
2. Foreign object stuck.