GETTING STARTED

Filling the Auxiliary Tank with Diesel Exhaust Fuel (DEF)

OPERATION

Part 

No.

Description

1

Swivel Connector for Submerged 

Pump

2

Submersible DEF Pump

3

Delivery Hose

4

Manual Delivery Nozzle for DEF

Part 

No.

Description

5

Cable for DEF (12V) Power  

Supply with I/O Switch

6

Plastic Filler Cap with Vent

7

DEF Poly Tank (10 Gal/50L)

8

Electrical Buse

9

Diesel Cylinder Space

1.   Before filling make sure the tank has no defects in the structure or equipment.

2.  Fill the tank slowly to prevent splashing fluid.

3.  When filling this tank, do not fill beyond 95% of capacity (approximately 9.5 gallons) to allow for 

expansion and to alleviate spills or vapors emitting into the atmosphere.

Before assembly, ensure you have all parts according to the contents list below. If any 

parts are missing or damaged, contact us for replacement.

7

8

1

4

5

9

2

3

6

Securing and Transporting Filled Auxiliary Tank

1.   The DEF Tank must be fully recessed into the JDI-AFT106 Diesel Tank before transporting 

to avoid movement.

2.  Make sure the lowest cylinder bottom fits into the diesel cylinder space.

3.  DO NOT place the tank inside a trunk or passenger compartment.

Содержание JDI-AFT106

Страница 1: ... MANUAL For Use With JDI AFT106 Part No JDI DEF10 151 Snyder Ave Barberton OH 44203 Rev 7 2021 READ AND SAVE THIS MANUAL FOR SERVICE ASSISTANCE CALL 800 433 0708 OR VISIT JOHNDOW COM FOR WARRANTY INFORMATION PLEASE CALL 800 433 0708 DATE OF PURCHASE ...

Страница 2: ...the tank Leave a minimum 5 empty space to allow the expansion of the fuel if the tank is exposed to high temperatures To avoid damage to the 12V transfer pump only use within the following timelines Maximum of 30 minutes of continuous use in normal continuous use in normal conditions Maximum of 2 minutes in bypass mode Regulations for the transportation of diesel fuel vary by state It is the vehic...

Страница 3: ...fects in the structure or equipment 2 Fill the tank slowly to prevent splashing fluid 3 When filling this tank do not fill beyond 95 of capacity approximately 9 5 gallons to allow for expansion and to alleviate spills or vapors emitting into the atmosphere Before assembly ensure you have all parts according to the contents list below If any parts are missing or damaged contact us for replacement 7...

Страница 4: ...in the OPEN position 4 4 Start the transfer pump by placing the switch in the ON I position 5 Proceed with the transfer for a maximum of 30 minutes from the time the pump was turned ON DO NOT run pump when not transferring for more than two minutes 6 Fill the DEF Tank to desired level 1 Stop the transfer pump by placing the switch in the OFF O position 2 Relieve all residual pressure in the hose b...

Отзывы: