John Wood STORAGE BOOSTER TANK Скачать руководство пользователя страница 3

- 3 -

tenance and service must be provided. Water lines and the
storage tank should be protected from freezing tempera-
tures. Do not install the storage tank in outdoor unprotected
areas. It is desirable to have a floor drain nearby to permit
easy draining if necessary.

Circulator Pump

A circulator pump is not supplied. Use only a bronze body
model rated for 110/120 volts, 60Hz. Install in accordance
with the pump manufacturer’s instructions using standard
plumbing practices.

Plumbing Connections

The main parts and features of your storage booster tank
are identified in Figure 1. Install plumbing according to
Figure 2 for single storage tank and according to Figure 3
for multiple storage tank systems.
1. Ensure the storage tank is level before starting installa-

tion.

2. Install circulation loop as shown using 19mm (¾ in.)

copper pipe.

3. Install the cold water supply piping into a tee between

the circulator discharge and the boiler coil inlet.

4. Connect the boiler supply line to the combination return

and drain valve.

5. Connect hot water supply to top tank fitting.
6. Install 19mm (¾ in.), 150 psi Temperature and Pressure

Relief Valve into the tank as shown.

7. A check valve may be installed between the cold water

tee connection and the circulator. This will force the cold
water through the coil first.

NOTE:

The check valve can often be noisy and cause

reduced supply pressures. For multiple storage tank sys-

ACCESS
DOORS

SUPPLY (TO BOILER
TANKLESS COIL)

T&P VALVE (SOME
MODELS WILL HAVE
A SIDE MOUNT FOR
THIS VALVE)

HOT

WATER

OUTLET

ANODE

THERMOSTAT

CONTROL

THERMOSTAT
RETAINER

COMBINATION
RETURN &
DRAIN VALVE

JUNCTION BOX

Figure 2:  Single Storage Booster Plumbing Diagram

COMBINATION RETURN

& DRAIN VALVE

STORAGE
BOOSTER

TANK

TANKLESS

COIL BOILER

HOT

T&P VALVE

(FOR SOME

MODELS)

HOT

T&P VALVE

CIRCULATOR

PUMP

CHECK VALVE

EXPANSION TANK (OPTIONAL)

PRESSURE

REGULATOR

(OPTIONAL)

COLD

Figure 3:  Multiple Storage Booster Plumbing Diagram

COMBINATION RETURN

& DRAIN VALVE

STORAGE
BOOSTER

TANK

STORAGE
BOOSTER

TANK

TANKLESS

COIL BOILER

HOT

T&P VALVE

(FOR SOME

MODELS)

HOT

HOT

T&P VALVE

CIRCULATOR

PUMP

CHECK VALVE

EXPANSION TANK (OPTIONAL)

PRESSURE

REGULATOR

(OPTIONAL)

COLD

CHECK

VALVE

T&P VALVE

IMPORTANT

Do not apply heat directly to tank fittings when making
sweat connections. They contain non-metallic material.

Figure 1:  Main Parts and Features

WARNING

The water heating source piping and components con-
nected to the tank must be suitable for potable water use.
TOXIC chemicals such as used for boiler treatment must
not be introduced into the tank.

Содержание STORAGE BOOSTER TANK

Страница 1: ...vice or maintenance can cause injury or property damage Refer to this manual For assistance or additional infor mation consult a qualified installer serv ice agency or the electric utility FOR YOUR SA...

Страница 2: ...energy supply system Install the valve into the opening provided on the storage tank or other approved system location Provide tubing so that any discharge from the valve will exit within 152mm 6 in...

Страница 3: ...alve may be installed between the cold water tee connection and the circulator This will force the cold water through the coil first NOTE The check valve can often be noisy and cause reduced supply pr...

Страница 4: ...4 The thermostat is rated for a maximum inductive current of 7 FLA at 120 VAC Do not exceed this rating for the circuit 5 Do not install or connect electrical heating elements to this tank Filling NO...

Страница 5: ...line 2 The water manually discharged will not cause any bod ily injury or property damage The water may be extremely hot While standing clear of the outlet discharge water may be hot lift the lever an...

Страница 6: ...Depending on water conditions an anode can last from one to ten years Many localities treat their water and this can have a significant effect on the life of your heater Water conditioning such as ove...

Страница 7: ...mited to one replacement component part for each original part 3 Return of Defective Water Heater and Component Parts Manufacturer reserves the right to examine the alleged defect in the water heater...

Страница 8: ...ater or any component part s claimed to be defective or any expense incurred to remedy any defect in the product Such charges may include but are not necessarily limited to a All freight shipping hand...

Отзывы: