background image

7

Extraction (Ducted)

The cooker hood is more effective when installed in the 
extraction mode (ducted to the outside).

Venting kits may be purchased through your retailer or 
DIY store, and must be evacuated through an outside 
vent of ø125 (5ins) or ø150mm (6ins).

The ducting used must be manufactured from fire 
retardent material conforming to the relevant British 
Standard or DIN 4102-B1.

When the cooker hood is ducted to the outside 
the charcoal filter must be removed.

 

 Fitting 

the 

Ducting

•  Fit the ø150mm (6ins) ducting to the spigot on top of 

the hood body as illustrated.

•  When using ø125mm (5ins) ducting fit 

item 9

 and 

10

 

on to the spigot on the top of the hood body as illus-
trated.

•  For the best performance use the shortest possible run 

of ducting and we recommend the use of rigid pipe in 
preference to flexible hose as this will improve the flow 
of air while reducing turbulence, which causes noise and 
a loss of performance.

•  If the room where the cooker hood is to be used contains 

a fuel burning appliance such as a central heating boiler, 
then its flue must be be of the room sealed or balanced 
flue type.

•  If other types of flue or appliances are fitted ensure that 

there is an adequate supply of air to the room.

•  The cooker ducting when fitted in the extraction mode 

must never be connected to central heating flues, radiators 
or water heaters.

Recirculation Mode

The cooker hood is supplied specified for use in the recircula-
tion mode, with the charcoal filter fitted. 

In the recirculation mode contaminated air is passed through 
the charcoal filter to be purified and recirculated into the kitch-
en through the grille outlets on either side of the chimney.
•  Assemble the two halves of the ducting extension pipe 

item 14.

•  Push-fit  the extension pipe on to the ducting spigot on 

top of the canopy.

•  Push-fit the recirculation adapter 

item

 

15

 on to extension 

pipe 

item

 

14

.

•  Insert the recirculation outlet extensions 

item 14.4

 into 

the recirculation adapter 

item

 

15

.

• The recircualtion grilles 

item

 

8a

 and 

8b 

must be fitted 

after the lower chimney 

item

 

2.2

 has been fitted.

•  Ensure the activated charcoal filter has been fitted.

9

ø 150

ø 125

10

14

14.1

15

8a

8b

Содержание JLBIHD105

Страница 1: ...JLBIHD105 built in cooker hood Instruction manual...

Страница 2: ...om where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other types of flue or appliances a...

Страница 3: ...Connections 9 Electrical Requirements 9 Electrical Connection 9 Installing the Cooker Hood 5 Installation Requirements 5 Unpacking 5 Fitting the Wall Brackets 6 Fitting the Canopy Hood 6 Extraction 7...

Страница 4: ...4 Description of the Appliance 650 min 490 120 108 259 150 min 680 max 880 680 260 300 90 132 433 80 100 gas and electrical hob gas and electrical hob...

Страница 5: ...llation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation Unpacking Before unpacking the cooker hood position the carton...

Страница 6: ...hob and mark two hole centres at 116 mm either side of the vetical line Drill 8 mm holes at all the centre points marked Insert the wall plugs not supplied in the holes Fix the brackets using the scre...

Страница 7: ...ins a fuel burning appliance such as a central heating boiler then its flue must be be of the room sealed or balanced flue type If other types of flue or appliances are fitted ensure that there is an...

Страница 8: ...stack item 2 1 and the canopy Secure the chimney stack to the canopy using the two screws item 12c 2 9 x 9 5mm supplied After the chimney has been secured into position insert the two plastic recircu...

Страница 9: ...the cooker hood Remove the grease filters see paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan This appliance...

Страница 10: ...rculation mode the contaminated air enters the cooker hood through the grease filters The air is cleaned by passing through the charcoal filters before being passed back into the kitchen through the g...

Страница 11: ...nd the control panel Grease Filters The Grease Filters absorb grease and dust during cooking to help keep the cooker hood clean inside and should be cleaned approximately once every two month or more...

Страница 12: ...hooks as illustrated Position the new charcoal filter in the position marked and while holding the filter replace the fixing hooks as illustrated This appliance can be a possible fire hazard if the gr...

Страница 13: ...ked The safety cut out device has been tripped Tum off the hob and then wait for the device to reset Repairs and After Sales Service In the event of your appliance requiring service or if you wish to...

Страница 14: ...der no circumstances should you attempt to repair the hob yourself Repairs carried out by inexperienced persons may cause injury or serious malfunctioning Contact our extended warranty administrators...

Страница 15: ......

Страница 16: ...436003485_02 060822 John Lewis Partnership 171 Victoria Street London SW1E 5NN www johnlewis com 0806...

Отзывы: