General Instructions
1.
Study the engineering layout drawing to confirm the proper seal
arrangement for the pump being used. Types 5610V and 5610VQ seals
are designed for versatility and can be assembled in various ways.
The following instructions describe the standard configurations.
2.
To assure satisfactory operation, handle the seal with care. Take
particular caution to see that the lapped sealing faces are not
scratched or damaged.
Preparing the Equipment
1.
Check seal chamber dimensions and finishes:
2.
Measure axial end play: Sizes to 3.000" = 0.003" FIM max.
3.000" and greater = 0.005" FIM
max.
3.
Determine squareness of seal chamber face to shaft:
Rotating Mating Ring
Sizes to 3.000" = 0.005" FIM max.
3.000" and greater = 0.007" FIM max.
Rotating Seal Head
Sizes to 3.000" = 0.002" FIM max.
3.000" and greater = 0.003" FIM max.
4.
Measure shaft runout:
Sizes to 3.000" = 0.002" FIM max.
3.000" and greater = 0.003" FIM
63
SHAFT OR SLEEVE
0
.
040
L
G
. X
20˚
CHAM.
BORE
0
D
+
0
.
000
"
-
0
.
002
"
6
3
0
.
040
"
20˚
MOVE SHAFT IN AXIAL DIRECTION
BY HAND. NOTE MEASUREMENT
ON DIAL INDICATOR
MOUNT
DIAL INDICATOR
ON SHAFT
TURN SHAFT BY HAND AND NOTE
MEASUREMENT ON DIAL INDICATOR
MOUNT
DIAL INDICATOR
ON SHAFT
T
TURN SHAFT BY HAND AND NOTE
MEASUREMENT ON DIAL INDICATOR
MOUNT
DIAL INDICATOR
ON SEAL CHAMBER
FACE
Assemble the Type 5610V as follows, referring to the applicable
engineering layout drawing.
NOTE:
These instructions apply to a rotating mating ring configuration.
The seal assembly and mating ring positions could be reversed
should an application require.
NOTE:
Elastomeric O-rings can be damaged or destroyed if care is not
taken. Prior to assembly of O-ring into groove, make sure groove
is clean and free of foreign materials. Lubricate both groove and
O-ring prior to installation with light lube oil (SAE #10 or #20) or
silicone grease (such as Dow Corning compound #4). For ethylene
propylene elastomers, do not lubricate with petroleum products.
1.
Place gland plate on table with gasket side facing up.
2.
Install lubricated O-ring into outside diameter (OD) groove of mating
ring.
3.
Stand sleeve on its base and slide mating ring over sleeve, align pins,
and press in place.
4.
Install set screws in collar.
5.
Loosely attach the spacers to the collar with cap screws.
6.
Set the gland plate assembly gasket side down on table. Install
collar on gland plate assembly and engage spacers into groove,
aligning spacers with pipe taps of gland plate. Uniformly finger
tighten the cap screws.
7.
Install lubricated O-ring into OD groove of retainer.
8.
Place spring inside retainer.
9.
Insert O-ring in retainer, ensuring that the O-ring is past the drive
slots.
10.
Align ears on primary ring with slots on the retainer and press into
bore of retainer. Make sure primary ring is engaged into slots and
moves freely.
11.
Place gland plate onto table with gasket side up.
12.
Insert seal assembly in gland plate, align pins, and press in place.
Turn gland plate over and confirm that retainer is flush with end of
gland plate.
13.
Clean faces of primary and mating rings with denatured alcohol
and a lint-free cloth.
14.
Making sure seal face does not fall out, slide gland plate sub-
assembly over sleeve until faces touch.
Part Name
1
Mating Ring
7
Collar
13
Gasket
2
O-ring
8
Set Screws
14
Snap Ring
3
Primary Ring
9
Spacers
15
O-ring
4
O-ring
10
Cap Screws
5
Sleeve Assembly
11
Gland Plate Assembly
6
O-ring
12
Spring
Type 5610V Single O-ring Cartridge Seal Assembly
NOTE:
If measured dimensions exceed those values given, correct the equipment to meet specifications prior to seal installation.
Typical Type 5610V Single O-Ring Cartridge
Seal Arrangement
1
5
4
3
12
8
14
13
11
9
7
15
10
6
2
TYPE 5610V/5610VQ
SINGLE O-RING CARTRIDGE SEAL
Installation, Operation & Maintenance Instructions
PAGE
2