background image

General Instructions

1.

Study the engineering layout drawing to confirm the proper seal
arrangement for the pump being used. Types 5610V and 5610VQ seals 
are designed for versatility and can be assembled in various ways. 
The following instructions describe the standard configurations.

2.

To assure satisfactory operation, handle the seal with care. Take 
particular caution to see that the lapped sealing faces are not
scratched or damaged.

Preparing the Equipment

1.

Check seal chamber dimensions and finishes:

2.  

Measure axial end play:                Sizes to 3.000" = 0.003" FIM max.

                                                           3.000" and greater = 0.005" FIM

max.

3.  

Determine squareness of seal chamber face to shaft:

                                                              Rotating Mating Ring 
                                                              Sizes to 3.000" = 0.005" FIM max.
                                                              3.000" and greater = 0.007" FIM max.

                                                              Rotating Seal Head 
                                                              Sizes to 3.000" = 0.002" FIM max.
                                                              3.000" and greater = 0.003" FIM max.

4.  

Measure shaft runout:

                                                              Sizes to 3.000" = 0.002" FIM max.
                                                              3.000" and greater = 0.003" FIM 

 

 

 

 

 

 

 

 

 

 

 

63

SHAFT OR SLEEVE

0

.

040

 L

G

. X 

20˚

 CHAM.

BORE

0

+

0

.

000

"

-

 

0

.

002

"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

0

.

040

"

20˚

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOVE SHAFT IN AXIAL DIRECTION

BY HAND. NOTE MEASUREMENT

ON DIAL INDICATOR

MOUNT

DIAL INDICATOR

ON SHAFT

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

TURN SHAFT BY HAND AND NOTE

MEASUREMENT ON DIAL INDICATOR

MOUNT

DIAL INDICATOR

ON SHAFT

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

TURN SHAFT BY HAND AND NOTE

MEASUREMENT ON DIAL INDICATOR

MOUNT

DIAL INDICATOR

ON SEAL CHAMBER

FACE

Assemble the Type 5610V as follows, referring to the applicable
engineering layout drawing.

NOTE:

 These instructions apply to a rotating mating ring configuration.

The seal assembly and mating ring positions could be reversed
should an application require.

NOTE:

 Elastomeric O-rings can be damaged or destroyed if care is not

taken. Prior to assembly of O-ring into groove, make sure groove 
is clean and free of foreign materials. Lubricate both groove and 
O-ring prior to installation with light lube oil (SAE #10 or #20) or
silicone grease (such as Dow Corning compound #4). For ethylene
propylene elastomers, do not lubricate with petroleum products.

  

1.

 Place gland plate on table with gasket side facing up.  

  

2. 

Install lubricated O-ring into outside diameter (OD) groove of mating
ring.

  

3.

 Stand sleeve on its base and slide mating ring over sleeve, align pins,

and press in place.

  

4.

 Install set screws in collar.

 5.

 Loosely attach the spacers to the collar with cap screws.

  

6.

 Set the gland plate assembly gasket side down on table. Install

collar on gland plate assembly and engage spacers into groove,
aligning spacers with pipe taps of gland plate. Uniformly finger
tighten the cap screws.

  

7.

 Install lubricated O-ring into OD groove of retainer.

  

8.

 Place spring inside retainer.

  

9.

 Insert O-ring in retainer, ensuring that the O-ring is past the drive

slots.

10.

 Align ears on primary ring with slots on the retainer and press into

bore of retainer. Make sure primary ring is engaged into slots and
moves freely.

11.

 Place gland plate onto table with gasket side up.

12.

 Insert seal assembly in gland plate, align pins, and press in place. 

Turn gland plate over and confirm that retainer is flush with end of
gland plate.

13.

 Clean faces of primary and mating rings with denatured alcohol

and a lint-free cloth.

14.

 Making sure seal face does not fall out, slide gland plate sub-

assembly over sleeve until faces touch.

Part Name

 1  

Mating Ring

               7  

Collar

                                13  

Gasket

 2  

O-ring

                        8  

Set Screws

                       14  

Snap Ring 

 3  

Primary Ring              

9  

Spacers                             

15  

O-ring

 4  

O-ring                       

10  

Cap Screws

 5  

Sleeve Assembly     

11  

Gland Plate Assembly

 6  

O-ring                       

12  

Spring                                   

Type 5610V Single O-ring Cartridge Seal Assembly

NOTE:

If measured dimensions exceed those values given, correct the equipment to meet specifications prior to seal installation.

Typical Type 5610V Single O-Ring Cartridge 
Seal Arrangement

1

5

4

3

12

8

14

13

11

9

7

15

10

6

2

TYPE 5610V/5610VQ

SINGLE O-RING CARTRIDGE SEAL

Installation, Operation & Maintenance Instructions

PAGE

2

Содержание 5610V

Страница 1: ...3 The seal is designed exclusively for sealing rotating shafts The manufacturer cannot be held liable for use of the seal for purposes other than this 4 The seal must only be used in technically perfect condition and must be operated within the recommended performance limits in accordance with its designated use set out in these installation instructions Dry running often indicated by a squealing ...

Страница 2: ...l SAE 10 or 20 or silicone grease such as Dow Corning compound 4 For ethylene propylene elastomers do not lubricate with petroleum products 1 Place gland plate on table with gasket side facing up 2 Install lubricated O ring into outside diameter OD groove of mating ring 3 Stand sleeve on its base and slide mating ring over sleeve align pins and press in place 4 Install set screws in collar 5 Loose...

Страница 3: ...25 3 338 1 500 2 187 2 250 2 680 4 875 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 525 3 599 1 625 2 312 2 375 2 812 5 000 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 562 3 766 1 750 2 406 2 480 2 918 5 250 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 563 3 875 1 875 2 549 2 625 2 918 5 250 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 563 3 875 2 000 2 673 2 750 3 015 5 500 2 963 1 601 2 312 1 032 2...

Страница 4: ...lywater is a registered trademark of American Polyware Co GLAND BOLTS SPACERS CAP SCREWS Type 5610VQ Oversize Bore Single Cartridge Dimensional Data inches Seal D4 Min Size D1 D3 Min Max D26 L12 L23 L39 L56 L90 L91 L92 M N Turn Diam 1 375 1 939 2 875 3 023 5 375 2 062 1 446 2 062 0 625 2 125 0 791 0 666 0 562 4 062 3 268 1 750 2 406 3 500 3 925 6 500 2 156 1 487 2 125 0 656 2 187 0 744 0 619 0 687...

Страница 5: ...t outside the seal The equipment instruction manual should be consulted to check for any special pre cautions 2 Ensure that the equipment is isolated by the appropriate valves Check that the fluid is drained and pressure is fully released Maintenance No maintenance of a seal is possible while installed Therefore it is recommended that a spare seal unit be held in stock to allow immediate replaceme...

Страница 6: ... 625 H SP 1030367 H SP 1030399 1 750 H SP 1030368 H SP 1030400 1 875 H SP 1030369 H SP 1030401 2 000 H SP 1030370 H SP 1030402 2 125 H SP 1030371 H SP 1030403 2 250 H SP 1030371 H SP 1030404 2 375 H SP 1030373 H SP 1030405 2 500 H SP 1030374 H SP 1030406 2 625 H SP 1030375 H SP 1030407 2 750 H SP 1030376 H SP 1030408 2 875 H SP 1030377 H SP 1030409 3 000 H SP 1030378 H SP 1030410 3 125 H SP 103037...

Страница 7: ...TYPE 5610V 5610VQ SINGLE O RING CARTRIDGE SEAL Installation Operation Maintenance Instructions PAGE 7 ...

Страница 8: ...ns without prior notice It is dangerous to smoke while handling products made from PTFE Old and new PTFE products must not be incinerated ISO 9001 and ISO14001 Certified details available on request 2015 John Crane Revised 10 15 www johncrane com IOM 5610 5610VQ NorthAmerica United States of America Tel 1 847 967 2400 Fax 1 847 967 3915 Europe United Kingdom Tel 44 1753 224000 Fax 44 1753 224224 L...