background image

  

5.

 If the pumped fluid is hazardous or toxic, appropriate precautions 

must be taken to ensure that any seal leakage is adequately
contained. Further information on sealing hazardous or toxic fluids
should be obtained from John Crane prior to seal installation. 

  

6.

 Fluorocarbon components should never be burned or incinerated 

as the fumes and residues are highly toxic. If fluorocarbons are
accidentally heated above 400˚C/750˚F, they can decompose.
Protective gloves should be worn as hydrofluoric acid may be present.

  

7.

 PTFE components should never be burned or incinerated as the

fumes are highly toxic. 

These instructions are for the installation and operation of
a seal as used in rotating equipment and will help to avoid
danger and increase reliability. The information required
may change with other types of equipment or installation
arrangements. These instructions must be read in
conjunction with the instruction manuals for both the 
pump and any ancillary equipment.

If the seal is to be used for an application other than that originally
intended or outside the recommended performance limits, John Crane
must be contacted before its installation and use.

Any warranty may be affected by improper handling, installation, or use
of this seal. Contact John Crane for information as to exclusive product
warranty and limitations of liability. 

If questions or problems arise, contact your local John Crane representative.
or the original equipment manufacturer, as appropriate.

John Crane mechanical seals are precision products and
must be handled appropriately. Take particular care to
avoid damage to lapped sealing faces and to flexible
sealing rings. Do not excessively compress the seal
before or during installation.

Safety Instructions

  

1.

 The following designations are used in the installation instructions to

highlight instructions of particular importance.

      

NOTE: 

Refers to special information on how to install or
operate the seal most efficiently.

      

Refers to special information or instructions directed
towards the prevention of damage to the seal or its
surroundings. 

      

Refers to mandatory instructions designed to
prevent personal injury or extensive damage to the
seal or its surroundings.

  

2.

 Installation, removal, and maintenance of the seal must be carried out

only by qualified personnel who have read and understood these
installation instructions.

  

3.

 The seal is designed exclusively for sealing rotating shafts. The

manufacturer cannot be held liable for use of the seal for purposes
other than this.

  

4.

 The seal must only be used in technically perfect condition, and

must be operated within the recommended performance limits in
accordance with its designated use set out in these installation
instructions.

Dry running — often indicated by a squealing noise from 
the seal area — will cause overheating and scoring or
other damage to the sealing surfaces, resulting in
excessive leakage or a much shortened seal life.

Before startup, ensure that all personnel and
assembly equipment have been moved to a safe 
distance so there is no contact with rotating parts
on the pump, seal, coupling, or motor.

WARNING:

Seal installation should be handled only by qualified
personnel. If questions arise, contact the local 
John Crane representative. Improper use and/or
installation of this product could result in injury to
the person and/or harmful emissions to 
the environment, and may affect any warranty 
on the product. Please contact the company for
information as to exclusive product warranty 
and limitations of liability.

Before Starting the Equipment

  

1.

 Check the pump at the coupling for proper alignment of the driver 

or motor.

  

2.

 Ensure that the gland plate nuts/bolts are securely tightened

according to the pump manual instructions, and that all screws 
are securely fastened.

  

3.

 Complete the assembly of the pump, and turn the shaft (by hand if

possible) to ensure free rotation.

  

4.

 Consult all available equipment operating instructions to check for

correctness of all piping and connections, particularly regarding seal
recirculation/flush, heating or cooling requirements, and services
external to the seal.

                               This mechanical seal is designed to operate in a liquid

so the heat energy it creates is adequately removed.
Therefore, the following check should be carried out
not only after seal installation, but also after any 
period of equipment inactivity.

  

5.

 Check that the seal chamber fluid lines are open and free of any

obstruction, and ensure that the seal chamber is properly vented  
and filled with liquid — refer to the pump instruction manual.

ATTENTION

ATTENTION

ATTENTION

!

ATTENTION

ATTENTION

!

TYPE 5610V/5610VQ

SINGLE O-RING CARTRIDGE SEAL

Installation, Operation & Maintenance Instructions

PAGE

1

Foreword

These instructions are provided to familiarize the user with the seal and its
designated use. The instructions must be read and applied whenever work
is done on the seal, and must be kept available for future reference.

Содержание 5610V

Страница 1: ...3 The seal is designed exclusively for sealing rotating shafts The manufacturer cannot be held liable for use of the seal for purposes other than this 4 The seal must only be used in technically perfect condition and must be operated within the recommended performance limits in accordance with its designated use set out in these installation instructions Dry running often indicated by a squealing ...

Страница 2: ...l SAE 10 or 20 or silicone grease such as Dow Corning compound 4 For ethylene propylene elastomers do not lubricate with petroleum products 1 Place gland plate on table with gasket side facing up 2 Install lubricated O ring into outside diameter OD groove of mating ring 3 Stand sleeve on its base and slide mating ring over sleeve align pins and press in place 4 Install set screws in collar 5 Loose...

Страница 3: ...25 3 338 1 500 2 187 2 250 2 680 4 875 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 525 3 599 1 625 2 312 2 375 2 812 5 000 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 562 3 766 1 750 2 406 2 480 2 918 5 250 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 563 3 875 1 875 2 549 2 625 2 918 5 250 2 744 1 487 2 125 0 593 2 187 0 744 0 619 0 563 3 875 2 000 2 673 2 750 3 015 5 500 2 963 1 601 2 312 1 032 2...

Страница 4: ...lywater is a registered trademark of American Polyware Co GLAND BOLTS SPACERS CAP SCREWS Type 5610VQ Oversize Bore Single Cartridge Dimensional Data inches Seal D4 Min Size D1 D3 Min Max D26 L12 L23 L39 L56 L90 L91 L92 M N Turn Diam 1 375 1 939 2 875 3 023 5 375 2 062 1 446 2 062 0 625 2 125 0 791 0 666 0 562 4 062 3 268 1 750 2 406 3 500 3 925 6 500 2 156 1 487 2 125 0 656 2 187 0 744 0 619 0 687...

Страница 5: ...t outside the seal The equipment instruction manual should be consulted to check for any special pre cautions 2 Ensure that the equipment is isolated by the appropriate valves Check that the fluid is drained and pressure is fully released Maintenance No maintenance of a seal is possible while installed Therefore it is recommended that a spare seal unit be held in stock to allow immediate replaceme...

Страница 6: ... 625 H SP 1030367 H SP 1030399 1 750 H SP 1030368 H SP 1030400 1 875 H SP 1030369 H SP 1030401 2 000 H SP 1030370 H SP 1030402 2 125 H SP 1030371 H SP 1030403 2 250 H SP 1030371 H SP 1030404 2 375 H SP 1030373 H SP 1030405 2 500 H SP 1030374 H SP 1030406 2 625 H SP 1030375 H SP 1030407 2 750 H SP 1030376 H SP 1030408 2 875 H SP 1030377 H SP 1030409 3 000 H SP 1030378 H SP 1030410 3 125 H SP 103037...

Страница 7: ...TYPE 5610V 5610VQ SINGLE O RING CARTRIDGE SEAL Installation Operation Maintenance Instructions PAGE 7 ...

Страница 8: ...ns without prior notice It is dangerous to smoke while handling products made from PTFE Old and new PTFE products must not be incinerated ISO 9001 and ISO14001 Certified details available on request 2015 John Crane Revised 10 15 www johncrane com IOM 5610 5610VQ NorthAmerica United States of America Tel 1 847 967 2400 Fax 1 847 967 3915 Europe United Kingdom Tel 44 1753 224000 Fax 44 1753 224224 L...

Отзывы: