14
3 WEBGUI
SETTING THE NAME OF THE DEVICE
When first connecting the modules,
be sure to follow this exact procedure!
• Connect the first module in the rack with your PC, using an RJ-45 Ethernet cable
(without using a switch!).
• Open a browser and surf to
START
• You will now enter the webGui. Go to the Configuration
Global menu:
• Change the name START to another name. Be sure to choose a logical name and
don’t forget this name!
This name is the only way to connect to the module later
on! It’s advisable to print this name, and label the devices.
• After you press
APPLY
, the module will restart. This will take about 25 seconds.
Afterwards, you can surf to the new name you just entered, to connect to the
module.
• Repeat this procedure with the next modules (1 at a time).
• When all modules have a new name, you can connect all modules to the same
network. The modules will now get a new IP address, but you can connect by surf-
ing to the right name (the unique name you gave the module in the previous steps).