background image

5

 

To avoid any risk of electrical shocks:

 

  Connect apparatus only to socket with protective earth connection.

 

  The mains plug shall remain readily operable.

 

  Pull out power plug to make the different connections of cables.

 

  To avoid electrical shock, do not open the housing of adapter.

 

 
 Maintenance

 

 

Only use a dry soft cloth to clean the cabinet.

 

Do not use solvent.

 

For repairing and servicing refer to qualified personnel.

 

 

Dispose according your local authority’s recycling processes

Содержание Colosseum 8500D

Страница 1: ...Colosseum 8500D user manual ...

Страница 2: ...cifications of the hardware and software described in these manuals at any time Unitron can not be held liable for any damages resulting from the use of this product Specifications are subject to change without notice 11 11 Unitron Frankrijklaan 27 B 8970 Poperinge Belgium T 32 57 33 33 63 F 32 57 33 45 24 email sales johansson be www johansson be www unitrongroup com ...

Страница 3: ...logging into the device 8 general configuration 10 about 10 global 11 factory reset 11 firmware upgrade 12 module restart 12 configuration of the input 13 configuration of the output 16 configuration of the MPEG setting 20 3 TECHNICAL SPECIFICATIONS 21 4 CONDITIONS OF WARRANTY 22 5 UHF FREQUENCY TABLE 23 6 POWER CONVERSION TABLE 24 ...

Страница 4: ...to the cabinet disconnect the power plug To avoid any risk of overheating Install the unit in a well aery location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation Do not place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes The unit must not be exposed to any source of heat sun heater Do not place any naked ...

Страница 5: ...readily operable Pull out power plug to make the different connections of cables To avoid electrical shock do not open the housing of adapter Maintenance Only use a dry soft cloth to clean the cabinet Do not use solvent For repairing and servicing refer to qualified personnel Dispose according your local authority s recycling processes ...

Страница 6: ... insert two screws min length from wall to screw head is 12 mm and diameter of screw head is max 11 5 mm The unit can be mounted with its connectors up or down but preferrably with the con nectors down PACKAGE CONTENTS Be sure all items listed below are included 1 Colosseum Ref 8500D 1 CAT6 ethernet cable 1 power cord 1 user manual 1 2 ...

Страница 7: ...A 19 2 Vertical Low 2 ASTRA 19 2 Horizontal Low 3 ASTRA 19 2 Vertical High 4 ASTRA 19 2 Horizontal High 5 Power cord NOTES Connect the 4 cables of a Quad Quattro LNB to prevent alarm messages Some LNB s require a lot of power to work properly The unit is able to deliver this power only when the 4 polarities are connected Do not change the bridges or load resistors ...

Страница 8: ... will be shown every time you browse to another menu item Please install one of the above browsers to avoid this LOGGING IN TO THE DEVICE Connect the module to your PC The module will obtain an IP address from your PC For this operation to work it is important that the PC is NOT set with a manual IP address Set the adapter to obtain an automatic IP address as explained in the following proce dure ...

Страница 9: ...rea Connection and choose Properties Double click on Internet Protocol Version 4 TCP IPv4 to enter the IP settings of your adapter Make sure the Obtain an IP address automatically checkbox is selected Click OK to save the settings ...

Страница 10: ...on file Save this file and mail it to us for analysis Open your network browser and surf to the name of the module The name of the first module is mod1 the name of the second module is mod2 You will now log in to the module After logging in the Summary window appears On this screen you see all the services streamed by this module The type of module the status and the language are visible on every ...

Страница 11: ...the module by simply typing it into your browser as the address and surf to it This is more convenient than using the IP address Just enter http hostname into your favorite browser not case sensitive and press enter FACTORY RESET All settings can be reset to default by means of a factory reset ...

Страница 12: ...he device click the Firmware upgrade menu item Click on the BROWSE button and open the upgrade file Click UPLOAD to send the file to the device this will install the new firmware on the device MODULE RESTART Press this menu item to restart the module ...

Страница 13: ...19 2 V Low Voltage The LNB voltage to select the polarization 13V Vertical polarization 18V Horizontal polarization Tone LNB tone to select low high band ON high band OFF low band DiSEqC control of a DiSEqC switch A B C D Band Satellite band Ku band common in Europe C band mostly used in the USA Ext Voltage Add 1V to the LNB voltage to compensate the cable losses for long coaxial cables Press APPL...

Страница 14: ...o every input thanks to a built in multiswitch Input One of the 4 labels configured in the previous step This selects the satellite input Frequency Transponder frequency Baud rate kBaud Press APPLY to confirm the parameters The module will now set the tuner to this frequency Wait until the correct parameters are loaded ...

Страница 15: ...s Green tuner locked Red tuner unlocked Level input signal level dBm BER Bit Error Rate SNR Signal to Noise Ratio dB The table Available services shows all the services found in the transponder Type Type of data TV service radio service locked service encoded unlocked service decoded Name Service name SID Service Identifier unique ID for a service ...

Страница 16: ...e to the MUX SETTINGS to configure the COFDM output parameters The 4 multiplexes are adjacent and only the frequency of the first mux needs to be configured the others will automatically be set according to this frequency and the bandwidth ...

Страница 17: ...own to the user Level dBm signal output level range 40 to 25 dBm Constellation QPSK 16 QAM 64 QAM Code Rate 1 2 2 3 3 4 4 5 5 6 7 8 Guard interval 1 32 1 16 1 8 1 4 Status ON the multiplex is active OFF the multiplex is not active Bandwidth 6 7 8 MHz Spectral inversion ON the frequency spectrum will be inverted OFF no frequency inversion Press APPLY to save the settings to the module ...

Страница 18: ...s are used to setup the logical channel numbering chan nel sequence on the TV TSID Transport Stream Identifier LCN Logical Channel Number Navigate to the SERVICE ASSIGNMENT menu to setup the TV and radio services at the output ...

Страница 19: ...rough the CAM card Encoded services will automatically pass through the CAM Icons add a new program to the list of services update the current service this icon will become active if some setting has changed delete the service from the list pressing this icon will remove the program permanently you can add it again NOTES The bitrate bar shows the current bitrate of the selected multiplex The numbe...

Страница 20: ...Electronic Program Guide tables to the TV s CAS forwarding Forward the Control Access System tables CAT EMM ECM to descramble the programs with a set top box CAT Conditional Access Table EMM Entitlement Management Message ECM Entitlement Control Message Block others Block private data PID share Enable sharing of the PES PCR and ECM ...

Страница 21: ...T NB OF OUTPUT 1 with 1 loop through 1 5 dB loss FREQUENCY RANGE 47 862 MHz MULTIPLEXES 8 CHANNEL BANDWIDTH 7 MHz VHF 8 MHz UHF MODULATION QPSK 16 QAM 64 QAM OFDM MODE 2K SPECTRAL INVERSION on off OUTPUT LEVEL 68 to 83 dBµV adjustable CONNECTORS RF 20 x F female Management 2 x RJ 45 DC banana sockets POWER SUPPLY 15 VDC CONSUMPTION 3 A OPERATING TEMPERATURE 0 to 40 C DIMENSIONS 280 x 260 x 150 mm ...

Страница 22: ...OES NOT COVER DAMAGE RESULTING FROM Misuse or use of the product out of its specifications Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accessories power supply adapters Installation in a defect system External cause beyond the control of Unitron N V such as drop accidents lightning water f...

Страница 23: ...90 36 590 598 37 598 606 V 38 606 614 39 614 622 40 622 630 41 630 638 42 638 646 43 646 654 44 654 662 45 662 670 46 670 678 47 678 686 48 686 694 49 694 702 50 702 710 51 710 718 52 718 726 53 726 734 54 734 742 55 742 750 56 750 758 57 758 766 58 766 774 59 774 782 60 782 790 61 790 798 62 798 806 63 806 814 64 814 822 65 822 830 66 830 838 67 838 846 68 846 854 69 854 862 5 UHF FREQUENCY TABLE...

Страница 24: ...50 V 75 Ω dBμV dBm 1 120 11 1 5 123 5 14 5 2 126 17 2 5 128 19 3 129 5 20 5 3 5 131 22 4 132 23 4 5 133 24 5 134 25 6 135 5 26 5 7 137 28 8 138 29 9 139 30 10 140 31 mV 75 Ω dBμV dBm 1 60 49 1 5 63 5 45 5 2 66 43 2 5 68 41 3 69 5 39 5 3 5 71 38 4 72 37 4 5 73 36 5 74 35 6 75 5 33 5 7 77 32 8 78 31 9 79 30 10 80 29 15 83 5 25 5 20 86 23 25 88 21 30 89 5 19 5 35 91 18 40 92 17 45 93 16 50 94 15 60 9...

Страница 25: ...25 ...

Страница 26: ...26 ...

Страница 27: ...27 ...

Страница 28: ...www unitrongroup com UNITRON NV Frankrijklaan 27 B 8970 Poperinge Belgium T 32 57 33 33 63 F 32 57 33 45 24 sales johansson be www johansson be ...

Отзывы: