background image

18 

 

Ref. 8550 and 8555 

•  Mux: The multiplex number (1 to 4) 
•  Frequency [kHz]: multiplex frequency in the VHF-UHF range:   

47000 to 830000 kHz. When entering a frequency outside this frequency range,  
an error will be shown to the user 

•  Baud Rate (kBaud): 6900 

•  Level [dBm]: signal output level (range: -40 to -25dBm) 

•  Constellation: 

o

 

16-QAM 

o

 

64-QAM 

 

•  Status:   

o

 

ON: the multiplex is active 

o

 

OFF: the multiplex is not active 

 

•  Bandwidth: 6/7/8 MHz 

 

•  Spectral inversion: 

 

o

 

ON: the frequency spectrum will be inverted 

o

 

OFF: no frequency inversion 

 

Press 

APPLY 

to save the settings to the module

 

 

Содержание Colosseum 8500

Страница 1: ...user manual Colosseum 8500 8501 8501UK 8505 8505UK 8506 8506UK 8550 8555...

Страница 2: ...eci cations of the hardware and software described in these manuals at any time Unitron cannot be held liable for any damages resulting from the use of this product Speci cations are subject to change...

Страница 3: ...LOGGING IN TO THE DEVICE 8 GENERAL CONFIGURATION 10 ABOUT 10 GLOBAL 11 FACTORY RESET 11 FIRMWARE UPGRADE 12 MODULE RESTART 12 CONFIGURATION OF THE INPUT 13 CONFIGURATION OF THE OUTPUT 16 CONFIGURATIO...

Страница 4: ...ower To avoid any risk of overheating Install the unit in a well aery location and keep a minimum distance of 15 cm around the apparatus for suf cient ventilation Do not place any items such as newspa...

Страница 5: ...nection The mains plug shall remain readily operable Pull out power plug to make the different connections of cables To avoid electrical shock do not open the housing of adapter Only use a dry soft cl...

Страница 6: ...t cable 1 power cord 1 user manual HARDWARE INSTALLATION The unit placed on a table 1 or mounted to the wall 2 For wall mounting drill two holes 23 cm apart and insert two screws min length from wall...

Страница 7: ...9 2 Vertical High 4 ASTRA 19 2 Horizontal High Power cord CI slots 1 2 3 4 5 6 NOTES Connect the 4 cables of a Quad Quattro LNB to prevent alarm messages Some LNB s require a lot of power to work prop...

Страница 8: ...functioning of the interface The webGUI will indicate this with a warning message This message will be shown every time you browse to another menu item Please install one of the above browsers to avoi...

Страница 9: ...Start Control Panel Enter the Network and Sharing Center and go to the Adapter Settings Right click on the Local Area Connection and choose Properties Double click on Internet Protocol Version 4 TCP I...

Страница 10: ...every screen In the picture above the status LED is green indicating that there are no alarms The alarm status is shown when you move over the status LED with your mouse GENERAL CONFIGURATION ABOUT Th...

Страница 11: ...ule by simply typing it into your browser as the address and surf to it This is more convenient than using the IP address Just enter http hostname into your favorite browser not case sensitive and pre...

Страница 12: ...the device click the Firmware upgrade menu item Click on the BROWSE button and open the upgrade le Click UPLOAD to send the le to the device this will install the new rmware on the device MODULE RESTA...

Страница 13: ...low or ASTRA 19 2VLow Voltage The LNB voltage to select the polarization o 13V Vertical polarization o 18V Horizontal polarization Tone LNB tone to select low high band o ON high band o OFF low band D...

Страница 14: ...every input thanks to a built in multiswitch Input One of the 4 labels configured in the previous step This selects the satellite input Frequency Transponder frequency Baud rate kBaud Press APPLY to...

Страница 15: ...Green tuner locked o Red tuner unlocked Level input signal level dBm BER Bit Error Rate SNR Signal to Noise Ratio dB The table Available services shows all the services found in the transponder Type T...

Страница 16: ...the rst mux needs to be con gured the others will automatically be set according to this frequency and the bandwidth NOTES Check if the MUX frequencies of the different modules do not overlap The TSID...

Страница 17: ...to the user Level dBm signal output level range 40 to 25dBm Constellation o QPSK o 16 QAM o 64 QAM Code Rate o 1 2 o 2 3 o 3 4 o 4 5 o 5 6 o 7 8 Guard interval o 1 32 o 1 16 o 1 8 o 1 4 Status o ON th...

Страница 18: ...cy range an error will be shown to the user Baud Rate kBaud 6900 Level dBm signal output level range 40 to 25dBm Constellation o 16 QAM o 64 QAM Status o ON the multiplex is active o OFF the multiplex...

Страница 19: ...s are used to setup the logical channel numbering channel sequence on the TV TSID Transport Stream Identifier LCN Logical Channel Number Navigate to the SERVICE ASSIGNMENT menu to setup the TV and rad...

Страница 20: ...hrough the CAM card Encoded services will automatically pass through the CAM Icons add a new program to the list of services update the current service this icon will become active if some setting has...

Страница 21: ...top box o CAT Conditional Access Table o EMM Entitlement Management Message o ECM Entitlement Control Message Block others Block private data PID share Enable sharing of the PES PCR and ECM ECM PID r...

Страница 22: ...LTIPLEXES 8 adjacent 4 adjacent CHANNEL BANDWIDTH 6 7 8 MHz MODULATION QPSK 16 QAM 64 QAM OFDM MODE 2K FORWARD ERROR CORRECTION 1 2 2 3 3 4 5 6 7 8 GUARD INTERVAL 1 4 1 8 1 16 1 32 MODULATION ERROR RA...

Страница 23: ...QUENCY RANGE 47 862 MHz MULTIPLEXES 8 adjacent 4 adjacent CHANNEL BANDWIDTH 6 8 MHz MODULATION 6 MHz 64 QAM 8 MHz 64 QAM 256 QAM MODULATION ERROR RATE 40 dB SPECTRAL INVERSION yes OUTPUT LEVEL 68 to 8...

Страница 24: ...NOT COVER DAMAGE RESULTING FROM Misuse or use of the product out of its specifcations Installation or use in a manner inconsistent with the technical or safety standards in force in the country where...

Страница 25: ...558 566 566 574 574 582 582 590 590 598 598 606 606 614 V 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 614 622 622 630 630 638 638 646 646 654 654 662 6...

Страница 26: ...58 57 56 55 53 5 52 51 50 mV 75 dB V dBm 1 1 5 2 2 5 3 3 5 4 4 5 5 6 7 8 9 10 15 20 25 30 35 40 45 50 60 70 80 90 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 60 63 5 66 68 69 5 71 72 73 7...

Страница 27: ...27...

Страница 28: ...28 UNITRON NV Frankrijklaan 27 B 8970 Poperinge Belgium T 32 57 33 33 63 F 32 57 33 45 24 sales johansson be www johansson be...

Отзывы: