background image

Digital SCR Multiswitch (Ref: 9744MC, 9746MC, 9748MC) 

 

 

 

 

 

4

 

 

 

 

1.

 

I

NTRODUCTION

 

Product description 

The 974xMC products are designed to support a wide range of new and existing multiswitch 

installations.  

 

Each 974xMC unit has: 

 

4 cascade-able LNB inputs from universal Quattro LNBF : VL HL VH HH 

 

1 terrestrial trunk. 

 

4, 8 or 16 SCR/Legacy outputs (9744MC, 9746MC or 9748MC) 

 

1 DC input. 

 

Each output can support a wide variety of satellite receivers : 

 

In legacy mode, the 974xMC outputs can be used as a standard multiswitch. 

 

In SCR mode, each 974xMC output supports up to 16UBs with all versions of the 

single cable technology. This includes OLT, SCR, CSS, EN50494, EN50607, and 

newer versions. 

 

As all outputs are independent, the installation can be a mix of legacy and SCR 

connections. 

 

The terrestrial part allows to support any service that operates below 1 GHz, which 

includes terrestrial reception, cable and DOCSIS reception. 

 

The trunks enable to cascade multiple products to support big installations of more than 

100 households in MDU applications, like apartments, or more than 100 rooms in 

hospitality environments, like hotels. 

 

The DC power can be inserted at any product. In cascaded systems, multiple power 

supplies might be needed, see “Diagnostic LED’s” for more information. The Johansson 

reference for the powersupply is 2460. 

Package contents 

 

1x Digital SCR Multiswitch (9744MC, 9746MC or 9748MC) 

Содержание 9744MC

Страница 1: ...User Manual SCR Multiswitch Ref 9744MC 9746MC 9748MC...

Страница 2: ...ves the right to change the specifications of the hardware and software described in these manuals at any time Unitron cannot be held liable for any damages resulting from the use of this product Spec...

Страница 3: ...Package contents 4 Mounting 5 Typical application for MultiChoice 6 2 INSTALLATION OF THE HARDWARE 7 3 CONFIGURATION OF THE MODULE 8 STB Power to Trunk Switch 8 Terrestrial amplifier 8 Diagnostic LED...

Страница 4: ...cable technology This includes OLT SCR CSS EN50494 EN50607 and newer versions As all outputs are independent the installation can be a mix of legacy and SCR connections The terrestrial part allows to...

Страница 5: ...Digital SCR Multiswitch Ref 9744MC 9746MC 9748MC 5 Mounting A B 9744MC 98 mm 179 mm 9746MC 179 mm 179 mm 9748MC 377 mm 179 mm...

Страница 6: ...Digital SCR Multiswitch Ref 9744MC 9746MC 9748MC 6 Typical application for MultiChoice...

Страница 7: ...trunks are DC isolated from each other so 13 V and 18 V can be supplied separately from trunk out to trunk in All 4 LNB trunks should always be cascaded or terminated with a DC blocked 75 Ohm termina...

Страница 8: ...always be terminated with a 75 Ohm terminator Diagnostic LED s Special high power startup mode status LED s blink alternating GREEN and RED This is a special mode active when starting up the device wh...

Страница 9: ...n When a compatible Set Top Box is connected and set in SCR Mode up to 16 User Bands can be generated and can be tuned independent of each other to any LNB input and transponder The 974xMC is compatib...

Страница 10: ...in to out gain Bypass 7 Max 5 Typical Amplified 4 Min 6 Typical Bypass 10 Max 8 Typical Amplified 1 Min 3 Typical Bypass 20 Max 16 Typical Amplified 2 Min 6 Typical In to SCR out gain Bypass 23 Max 17...

Страница 11: ...Input Max Power Consumption SCR mode 6W per pair of ports LNB emulation mode 2 1 W per port Ter Amp OFF DC from trunk lines out to in Yes not for terrestrial trunk Supply current to LNB switchable 50...

Страница 12: ...ventilation Do not place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes Do not place any naked flame sources such as lighted candles on the appar...

Страница 13: ...NSHIP AND DOES NOT COVER DAMAGE RESULTING FROM Misuse or use of the product out of its specifications Installation or use in a manner inconsistent with the technical or safety standards in force in th...

Страница 14: ...Digital SCR Multiswitch Ref 9744MC 9746MC 9748MC 14...

Страница 15: ...Digital SCR Multiswitch Ref 9744MC 9746MC 9748MC 15...

Страница 16: ...Digital SCR Multiswitch Ref 9744MC 9746MC 9748MC 16 UNITRON NV Frankrijklaan 27 B 8970 Poperinge Belgium T 32 57 33 33 63 F 32 57 33 45 24 sales unitrongroup com www unitrongroup com...

Отзывы: