background image

OCTO AV MODULATOR (REF. 8180) 

 

 

 

 

 

 

 

 

11

 

 

3.

 

S

AFETY 

I

NSTRUCTIONS

 

 

 

Read these instructions carefully before connecting the unit

 

 
 

    

To prevent fire, short circuit or shock hazard:

 

 

Do not expose the unit to rain or moisture. 

 

Install the unit in a dry location without infiltration or condensation of water. 

 

Do not expose it to dripping or splashing. 

 

Do not place objects filled with liquids, such as vases, on the apparatus. 

 

If any liquid should accidentally fall into the cabinet, disconnect the power plug. 

    

To avoid any risk of overheating:

 

 

Install the unit in a well aired location and keep a minimum distance of 15 cm around the 
apparatus for sufficient ventilation 

 

Do not place any items such as newspapers, tablecloths, curtains,  
on the unit that might cover the ventilation holes. 

 

Do not place any naked flame sources, such as lighted candles, on the apparatus  

 

Do not install the product in a dusty place  

 

Use the apparatus only in moderate climates (not in tropical climates) 

 

Respect the minimum and maximum temperature specifications  

    

To avoid any risk of electrical shocks

 

Connect apparatus only to socket with protective earth connection. 

 

The mains plug shall remain readily operable  

 

Pull out power plug to make the different connections of cables  

 

To avoid electrical shock, do not open the housing of adapter. 

 

 

Maintenance

 

  Only use a dry soft cloth to clean the cabinet. 
  Do not use solvent 
  For repairing  and servicing  refer to qualified personnel. 

 

Dispose according your local authority’s recycling processes

 

 

Содержание 8180

Страница 1: ...User Manual Octo AV Modulator Ref 8180 ...

Страница 2: ...OF WARRANTY 12 No part of this manual may be copied reproduced transmitted transcribed or translated into any language without permission Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time Unitron cannot be held liable for any damages resulting from the use of this product Specifications are subject to change without notice 1...

Страница 3: ...alog inputs each 1 video cinch 2 audio cinch L R processes up to 8 analog channels Multi TV standard support NTSC PAL SECAM B G I D K L M N 1 RF output 1 Test output 30dB Built in high power RF booster easy to configure with the Johansson button and 4 digits display selectable Region Standard Mode Output Channel adjustable RF Level Audio Level and Video Level very compact housing with detachable p...

Страница 4: ...pply socket DC power presence is indicated by flashing dots Connect the AV inputs Connect a coaxial cable to the output connector for distribution of the signal Connect a network analyser to the test port to control the signal quality Configure the Octo AV Modulator using the rotary button see below The power adapter can easily be replaced without disconnecting the product To do so open the top le...

Страница 5: ...OCTO AV MODULATOR REF 8180 5 1 4 Connecting the AV cables TOP VIEW BOTTOM VIEW ...

Страница 6: ...de is indicated by flashing dots on display Push the rotary button for 3 seconds to access the menu When you enter the configuration step the LEDs of the 8 AV CHANNELS will be GREEN Tap to select the channel plan from your region UHF E UHF Europe S38 E69 Lt1 E UHF Europe limited to CH60 S33 E60 Lt2 E UHF Europe limited to CH48 S27 E48 LAT A Latin America CH 14 79 When the region is updated all 8 m...

Страница 7: ...go to next step Tap to select the AV Channel you want to set AV Channel 1 to 8 For example if you want to set AV Channel 1 tap to confirm and scroll to the next step The LED of AV Channel 1 will stay GREEN In the previous step you have selected an AV channel Now in this step you can select the RF channel for the selected AV channel ...

Страница 8: ...lected the RF channel for an AV channel Now in this step you can select the RF Attenuator for the selected AV channel Tap to set the RF Attenuator Select between 0 20 dB in steps of 2dB 0dB maximum output level 105 BµV 20dB 85dBµV This way you can equalise your output signal Tap to confirm Scroll right to go to next step Tap to select the Audio Level Select between 0 and 7 in steps of 1 0 No atten...

Страница 9: ...ice is locked the display at startup will show 00 Turn the button to 50 and tap and the device will be unlocked RESET DEVICE To reset the device to factory settings unplug the power cord tap the rotary button and plug in the power cord Hold the rotary button until DONE is displayed FACTORY SETTINGS After RESET DEVICE Region Lt2 E LTE2 Europe Standard PLbG PAL BG Channels for modulators 1 8 S27 S29...

Страница 10: ...9 for FM PAL NTSC Video S N dB 54 100 White 1 Vpp Channel Plans UHF S38 E69 52 Ch 8 MHz spacing Lt1 E S33 E60 48 Ch 8 MHz spacing Lt2 E S27 E48 43 Ch 8 MHz spacing LTAM CH 14 79 65 Ch 6 MHz spacing RF Attenuator independent per modulator dB 20 in steps of 2dB RF Output Power 60dB IM3 RF Output Power per carrier dBµV dBµV 114 105 Test Port dB 30 Configuration Region Standard AV Channel RF Channel A...

Страница 11: ...on Do not place any items such as newspapers tablecloths curtains on the unit that might cover the ventilation holes Do not place any naked flame sources such as lighted candles on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climates not in tropical climates Respect the minimum and maximum temperature specifications To avoid any risk of electrical s...

Страница 12: ...ifications Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accessories power supply adapters Installation in a defect system External cause beyond the control of Unitron N V such as drop accidents lightning water fire improper ventilation THE WARRANTY IS NOT APPLIED IF Production date or serial...

Отзывы: