MNP85ENV00
Rev.02 (2014-01-07) Page 7 of 20
3.2 Reader behaviour when a jam is detected
The following configurations of switches allow you to choose how the banknote reader
should behave when there is a jam. To configure either one of them, the banknote
reader should be off. Select the suitable switch configuration, turn on the reader and
wait until all blue LEDs are on. You can then turn off the reader, as the setting is
saved in the EEPROM.
Once it is saved, you can return to the configuration of switches in normal operation
that you had decided, with switches 7 and 8 OFF.
Stack, resettable error
: When a banknote is jammed, it attempts to stack it without
validating it so the reader can be back in service. In this situation, the only way to
verify the truthfulness of a user claim is to rely on the machine audits to see if there
are any uncounted banknotes in the stacker
The other configuration is
don´t stack, resettable error
: In this configuration the
banknote remains in the position where it was stuck. This way you can verify that
there has been a problem when you remove the stacker. This way, the reader is out
of service until the jammed banknote is removed. In this situation, you can verify the
truthfulness of a user claim just by opening the stacker and seeing if there is a
jammed banknote.
SW1 SW2 SW3 SW7 SW8
OFF ON OFF ON OFF
3.3 Bill group acceptance
Dip switches 4 and 5 (BILL GROUP ACCEPTANCE) are used to inhibit or enable
whole groups of banknotes that have been previously loaded into the banknote
reader. When any of the dip switches are in OFF the group is accepted, while it is ON,
the group is inhibited. If you want to inhibit a specific banknote (not a group of
banknotes) you have to use inhibition with a different combination of dip switches,
explained in the next item, 'Testing and programming'.
3.4 Bit time adjustments.
Dip switch number 6, MDB ADJUST is used to adjust bit times in communication. It
can be used in cooperation with technical support service to install the BT11 on
special machines.
3.5 Testing
and
programming
To enter programming mode and communication with a PC, dip switch 8 must be
ON and dip switch 7 to OFF. This combination of switches is mandatory if you want to
connect the reader to a computer with the needed software installed. You don´t need
to set this combination for any other situation unless it is specifically mentioned on this
manual
SW7 SW8
OFF ON
SW1 SW2 SW3 SW7 SW8
OFF OFF ON ON OFF