2. Assembly and Commissioning Instructions
Setting Up Your Scale
The following example illustrates how to set the AUTO-OFF function to 180 seconds and to disable
the audible ‘beep’:
STEP 1:
Press ‘
ZERO
’ key to switch scale on.
STEP 2:
Press the ‘
HOLD
’ key for 3 seconds to enter ‘
SET-UP
’ mode.
STEP 3:
Press the ‘
ZERO
’ key to enter ‘
AOFF
’ mode.
STEP 4:
Press the ‘
HOLD
’ key to select ‘
180 S
’ indicating that the AUTO-OFF time is 180 seconds.
STEP 5:
Press the ‘
ZERO
’ key to select and return to ‘
AOFF
’ mode and press ‘
HOLD
’ to enter to
‘
BEEP
’ setup mode.
STEP 6:
Press the ‘
ZERO
’ key to enter ‘
BEEP
’ setup mode and press ‘
HOLD
’ again to select
between ‘
ON
’ and ‘
OFF
’ .
STEP 7:
Press the ‘
ZERO
’ key to decide and return to ‘
BEEP
’ set-up mode.
STEP 8:
Press the ‘
HOLD
’ key to select ‘
END
’ and press ‘
ZERO
’ to finish setting.
Operation Flow
Zero
Hold