TROUBLESHOOTING
PROBLEM
• There is no spark when lighting
the gas
CORRECTIVE ACTION
• Check that the unit is plugged in and the electrical
supply is switched on
• Check that the RCCB has not tripped (if fitted)
• Check the mains fuse has not blown
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
• The gas ring burns unevenly
• Check the main jet is not blocked and the burner
crown is clear of food particles.
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
INSTRUCTIONS FOR THE INSTALLER
Overall dimensions
Width: 590mm
Depth: 510mm
Cut out dimensions
Width: 560mm
Depth: 480mm
TECHNICAL DATA
Burner configuration
NG I
2H
(20)
LPG I
3+
(28~30/37)
Injector Dia.
(mm)
kW
Injector
Dia. (mm)
kW
Triple Flame (Rapid)
1.27
3.3
(314.5 L/h)
0.95
3.3
(239.7 g/h)
Semi rapid burner (Medium)
0.94
1.75
(166.8 L/h)
0.65
1.75
(127.1g/h)
Auxiliary burner (Small)
0.72
1.0
(95.3 L/h)
0.52
1.0
(72.7 g/h)
-27-