TROUBLESHOOTING
PROBLEM
• There is no spark when lighting
the gas
CORRECTIVE ACTION
• Check that the unit is plugged in and the electrical
supply is switched on
• Check that the RCCB has not tripped (if fitted)
• Check the mains fuse has not blown
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
• The gas ring burns unevenly
• Check the main jet is not blocked and the burner
crown is clear of food particles.
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
INSTRUCTIONS FOR THE INSTALLER
Overall dimensions
Width: 600mm
Depth: 540mm
Cut out dimensions
Width: 560mm
Depth: 480mm
TECHNICAL DATA
Burner
’s configuration
LPG I
3+
(28~30/37)
NG I2H (20)
Injector Dia.
(mm)
Diâm. Bicos (mm)
Injector Dia.
(mm)
kW
Triple
0.94
3.3 (239.7 g/h)
1.27
3.3 (314.5 g/h)
Semi rapid
0.65
1.75 (127.1g/h)
0.94
1.75 (166.8 g/h)
Rapid
0.83
2.7 (195.6 g/h)
1.13
2.7 (257.3 g/h)
-27-