TROUBLESHOOTING
PROBLEM
• There is no spark when lighting
the gas
CORRECTIVE ACTION
• Check that the unit is plugged in and the electrical
supply is switched on
• Check that the RCCB has not tripped (if fitted)
• Check the mains fuse has not blown
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
• The gas ring burns unevenly
• Check the main jet is not blocked and the burner
crown is clear of food particles.
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
INSTRUCTIONS FOR THE INSTALLER
Overall dimensions
Width: 310mm
Depth: 510mm
Cut out dimensions
Width: 265mm
Depth: 480mm
TECHNICAL DATA
Burner
’s configuration
NG I
2H
(20)
LPG I
3+
(28~30/37)
Injector Dia.
(mm)
kW
Injector
Dia.(mm)
kW
Rapid burner (medium)
1.11
2.7 (257.3 L/h)
0.83
2.7 (195.6 g/h)
Auxiliary burner (small)
0.72
1.0 (95.3 L/h)
0.52
1.0 (72.6 g(h)
-27-