66
D-mode
For choose the dry out protection mode. When water
sensor is applied, dry protection mode should be set to
detect dry protection. Default is “DETECT”.
OF-F
For choose over flow warning function. Default is no
overflow warning. If you want to use this function, please
set to “on”. Default is “OFF”.
OF-Time
For choose over flow warning function. Over flow
recovery time, after the warning of over flow and inverter
shut down, the duration from shut down to restart.
Default value is 30. Default duration is 30 minutes.
M-Mode
If water output is abnormal, and caused by reversed
motor phase sequence, you can try to reset this model
from “REV” to “FWD”. Default is “FWD”.
DebugMod
This value represents the operation mode of the inverter:
"economy" : the inverter is in economical mode,
automatic selection system based on photovoltaic energy
grid energy intervention; "Reliable" : the inverter is in a
reliable mode, the system detects the grid input and uses
the grid energy to ensure the maximum frequency
operation of the inverter; "Group control" : the inverter is
in the group control mode, and the inverter runs as a
slave; "3" : The inverter is in the motor parameter
detection mode (this mode is set by default when the
single-phase pump inverter is delivered from the factory.
After the motor parameter detection is completed, the
debugging mode will automatically switch to 0. If other
modes need to be switched, manual switch will be