CONTROL SYSTEM INSTRUCTION
NOTE:
The function and connection of the controller meets the
corresponding model of
controller manual.
The function and parameter of the spa meet the APPENDIX.
Display Message
Message
Meaning
Action Required
No message on display. Power has been cut off
to spa.
The control panel will be disabled until power returns.
The system reset the time of day on each power up. Spa
settings are preserved.
OHH
Overheat"- The spa has shut down. One of the
sensors detected 118egree F (approximately
47.8degree C) at the heater.
Do not enter the water. Remove the spa cover and allow
the water to cool. Once the heater has cooled, reset by
pushing any button. If the spa does not reset, shut off the
power to the spa and call the local dealer or service.
OHS
Overheat"- The spa has sh ut down. One of the
sensors detected that the spa water is 110egree
F(approximately 43.3 degree C).
Do not enter the water. Remove the spa cover and allow the
water to cool. At 107 degree F (approximately 41.7 degree
F), the spa should automatically reset. If the spa does not
reset, shut off the power to the spa and call the local
dealer for service.
ICE
Ice" - Potential freeze condition detected.
No action required. The pumps and the blower will
automatically activate regardless of the spa status.
SnA
Spa is shut down. The sensor that is plugged into
the "Sensor B" jack is not working correctly.
Check the sensor "B" plug connection to circuit board. If the
problem persists, contact the local dealer or service. (The
problem may appear temporarily in an overheat situation
and disappear when the heater cools).
SnS
Sensors are out of balance. If this is alternating
with temperature, it may just be temporary
condition. If the display shows only this message
(periodically blinking), the spa is shut down.
If the problem persists, contact the local dealer or service.
HFL
A substantial difference between sensors was
detected. This could indicate a flow problem.
Check water level in spa and the circulation system. Add
water if necessary. Be sure that slide-valves are open. Make
sure the circulation pump have been primed and has
power. Change the new filter cartridge.
LF
Persistent low flow problems. Displays on the
fifth occurrence of the "HFL" message within
24 hours. Heater is shut down, but other spa
functions to run normally.
Follow actions required for "HFL" message. Heating
capacity of the spa will not reset automatically; you may
press any button to reset or cycle the power off and on.
Dr
Inadequate water detected in heater. Displays
on
third occurrence of "dr" message. Spa is shut
down for 15 minutes.
Check water level in spa. Add water if necessary. Be sure
that slide-valves are open. Make sure the circulation pump
have been primed and has power. On the third consecutive
occurrence of the dr message (without a successful
heating cycle in between) the panel will display dr4.
Dry
Inadequate water detected in heater. Displays
on third occurrence of "dr" message. Spa is
shut down and will not reset in 15 minutes.
Check water level in spa. Add water if necessary. Be sure
that slide-valves are open. Make sure the circulation pump
have been primed and has power. Press any button to reset.
Pr
When your spa is first activated, it will go into
Priming mode.
See the 24 hour circulation pump operation. The Priming
mode will last for up to four minutes and then the spa will
begin to heat and maintain the water temperature in
Standard mode.
-F
-C
Temperature unknown
Temperature unknown
After 6minutes Pr mode, the temperature will be
displayed. After 6minutes Pr mode, the temperature will
be displayed