![JMA Wireless RET-200 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/jma-wireless/ret-200/ret-200_quick-start-manual_2020326004.webp)
RET-200 REPLACEMENT
REV. 010616
4
Fig. 4 – Aligning Screw Holes
Fig. 5 – RET Screws Fig. 6 – Dielectric Grease
Fig. 7 – Proper Dielectric Grease Application
3.
Once the screw holes are aligned, secure the motor to the housing with the four
screws. Ensure that all washers are in the correct order on the screw per Fig. 5 for
proper isolation.
4.
Apply the dielectric grease supplied with the spare motor to both connectors on
each end of the AISG cable – see Fig. 6 & 7. This provides additional moisture
and corrosion protection.
5.
Reconnect the AISG cable.
Do not use tools to tighten AISG cables, use hand
pressure, finger tight!
6.
You must perform a Calibration again prior to setting tilt.
Split Washer, Plastic Washer
Flat Washer