8-26
not operational during that timing.
RESET
HALL
DOOR
TIMER ON PH
That feature is most of the time used in hospital
or building with people with reduced mobility.
As soon the photocell is cut or released, the door
opened timer on hall call is reset. That gives
more time to place the car call when the person
gets in the car with a wheel chair…
YES/NO
0027
8.2.7. Parking level & timers:
OPTION
DESCRIPTION
UNIT
DM
PARKING RETURN
DELAY
Delay before return to parking level. Do not
enter a too small value because people that get
in the car will not have enough time to place
there car call. For simplex 60 sec. or more is
good. For groups, 30 to 40s is good.
0.1s
0024
ACT. EXCLUSIVE
PARKING LEVEL
Exclusive parking activation. On any type of
control,
the
adjuster
can
temporary
or
permanently program a specific parking level
for an elevator (Group or simplex). That parking
overrides the dispatcher parking.
YES/NO
0095
EXCLUSIVE PRK.
DOOR OPENED
On exclusive parking operation, door will be
opened or not at the parking level.
0.1s
0096
EXCLUSIVE PRK. FL.
LEVEL 1-TOP
On exclusive parking operation, specify the
floor level. The level can be: 1, 2, 3, 4, 5…
Example: for a parking at 2Z (second door
zone), write 2. If you write 0, the CPU will
correct with 1. If you enter a value greater than
top floor, the CPU will change for top floor.
n/a
0097
8.2.8. Car calls options:
OPTION
DESCRIPTION
UNIT
DM
CAR CALLS ANTI-
NUISANCE WITH PH
Activation of the protection of car call anti-
nuisance in regards to photocell.
YES/NO
0082
NO PASSENGER RUN
COUNT WITHOUT PH
If the car call anti-nuisance is activated, the
controller counts the number of call answered
without the photocell beam cut. When that
preset count is reached, all the car calls
registered will be cleared.
n/a
0083
TOP & BOTTOM
CARCALL CANCELLED
When that feature is activated, each time the
elevator stops at top or bottom floor, the car
calls are cleared.
YES/NO
0089
OPPOSITE DIRECT.
CAR CALL LOCKING
When that feature is activated, the controller
locks the car call in back of the actual direction.
Example: if the car moves up and is at 4th floor.
1C, 2C, 3C are not allow. Same principle in the
opposite direction.
YES/NO
0090
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...