SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
31215027
7-3
Hydraulic Oil
NOTE:
Hydraulic oils must have anti-wear qualities at least to API Ser
-
vice Classification GL-3, and sufficient chemical stability for
mobile hydraulic system service.
Aside from JLG recommendations, it is not advisable to mix oils
of different brands or types, as they may not contain the same
required additives or be of comparable viscosities. If use of
hydraulic oil other than standard UTTO is desired, contact JLG
Industries for proper recommendations.
Table 7-4. Hydraulic Oil
Hydraulic System
Operating
Temperature Range
S.A.E. Viscosity
Grade
+0° to + 180° F
(-18° to +83° C)
10W
+0° to + 210° F
(-18° to +99° C)
10W-20, 10W30
+50° to + 210° F
(+10° to +99° C
20W-20
Table 7-5. DTE 10 Excel 15 Specs
ISO Viscosity Grade
#15
Pour Point, Max
-65°F (-54°C)
Flash Point, Min.
360°F (182°C)
Viscosity
at 40° C
15.8 cSt
at 100° C
4.1cSt
at 100° F
15.8 cSt
at 210° F
4.1 cSt
Viscosity Index
168