SECTION 3 - MACHINE CONTROLS AND INDICATORS
31215000
3-15
6.
Enable Indicator/Footswitch
To operate any function, the footswitch must
be depressed and the function selected within
seven seconds. The enable indicator shows
that the controls are enabled. If a function is not selected
within seven seconds, or if a seven second lapse between
ending one function and beginning the next function, the
enable light will go out and the footswitch must be released
and depressed again to enable the controls.
Releasing the footswitch removes power from all controls
and stops all functions.
TO AVOID SERIOUS INJURY, DO NOT REMOVE, MODIFY OR DISABLE THE FOOTSWITCH
BY BLOCKING OR ANY OTHER MEANS.
7.
Platform Overload Indicator
Indicates the platform has been overloaded.
8.
Capacity Zone Indicator
Indicates the platform capacity zone for the
current position of the platform. Restricted
capacities are permitted at restricted platform
positions (shorter boom lengths and higher
boom angles).