SECTION 6 - JLG CONTROL SYSTEM
6-48
31215031
Pressing the ESC key
after starting calibration and
before calibration is complete will display the CAL FAILED
message. This will not disturb the prior calibration infor-
mation.
7.
Press ENTER
. The analyzer screen will read:
8.
If the platform is empty, press ENTER
. The screen
will read:
NOTE:
Accessory weight will reset to 0 lbs. each time the machine
is re-calibrated and will need to be re-entered.
NOTE:
The Accessory weight will be temporarily stored in the Con-
trol System until calibration has been completed success-
fully.
Refer to Table 6-8, Accessory Weights. Use the up and
down analyzer keys to enter the accessory weight(s) (in
lbs). When all the accessory weights are entered, press
ENTER
. The screen will read:
LOAD SENSING:
accessory xxxlbs:
Table 6-8. Accessory Weights
Accessory
Weight
SkyWelder (stick welder)
70 lb (32 kg)
SkyWelder Prep
Prep only = 15 lb (7 kg)
Full install = 70 lb (32 kg)
SkyCutter (plasma cutter)
70 lb (32 kg)
SkCutter / SkyWelder Combo
140 lb (64 kg)
Fire Extinguisher
45 lb (20 kg)
Overhead SoftTouch
80 lb (36 kg)
Work Surface
20 lb (9 kg)
NOTE:
Not all Accessories are available on every JLG model.
Some Accessory combinations are prohibited due to
excessive weight and/or load restriction. If any installed
JLG Accessories are labeled with weight decals but are
not listed in the table above, include their weight when
entering the ACC WEIGHT value.