SECTION 3 - MACHINE CONTROLS, INDICATORS, AND OPERATION
3-4
31215084
3. Lift/Lower Switch -
A three position, momentary con
-
tact lift control switch provides raising and lowering of
the platform when positioned to up or down.
4. Generator Start Switch (Optional) -
A momentary
contact, push button switch is provided to manually
start the optional generator
5. Overload Indicator (LSS) -
Indicates the platform has
been overloaded. An audible alarm will also signal
when the platform is overloaded.
NOTE:
If the Overload Indicator is illuminated, all functions will
be prevented from the platform controls. Using the
ground controls or manual descent, fully lower the
machine and reduce the weight in the platform to not
exceed the rated workload indicated on the capacity
decal.
6. Hourmeter -
The hourmeter indicates the number of
hours the machine has been operated.
7. Circuit Breaker -
If the circuit breaker opens this indi
-
cates a short or overload on the machine.
8. System Fault -
Illuminates when there is any type of
fault in the electrical system.